Compressibility of two polyvinyl siloxane interocclusal record materials and its effect on mounted cast relationships

被引:23
作者
Campos, AA [1 ]
Nathanson, D [1 ]
机构
[1] Univ Fed Ceara, Dept Odontol Restauradora, BR-60441750 Fortaleza, Ceara, Brazil
关键词
D O I
10.1016/S0022-3913(99)70034-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Addition silicones (polyvinyl siloxanes) are universally accepted as accurate and stable impression materials. They have also gained popularity as interocclusal record materials. However, it has not been defined. if it is possible to more with polyvinyl siloxanes without changing the recorded maxillomandibular relations. Purpose. This study examined the compressibility of 2 addition silicones as interocclusal record materials, analyzing the changes of maxillomandibular relations at the condyle region when different compressive forces are used to stabilize articulated casts. Material and methods. Sixteen interocclusal records, obtained from the same patient (8 of each polyvinyl siloxane, Blu-Mousse, Fast Set), were interposed between the patient casts ill a new measuring system obtaining 48 curves of load versus maxillomandibular positional changes in 3 axes (x, y, z). These curves were compared with curves obtained with the casts in maximum intercuspation without interocclusal records (reference curves). Analysis of variance was used to compare maxillomandibular positional changes among the 3 groups (n = 48 each): Blu-Mousse, Fast Set, and control group or maximum intercuspation without interocclusal record. Results. There mns no significant change in maxillomandibular relations when forces up to 1 kgf were: applied to stabilize the casts related by means of Blu-Mousse and Fast Set addition silicone interocclusal records. Conclusion. It is possible to use these polyvinyl siloxanes as interocclusal record materials without changing the recorded maxillomandibular relations.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 19 条
[1]   A NEW ELECTROMECHANICAL DEVICE TO MEASURE THE ACCURACY OF INTEROCCLUSAL RECORDS [J].
ASSIF, D ;
HIMEL, R ;
GRAJOWER, Y .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (06) :672-676
[2]  
BALTHAZAR Y, 1989, TYLMANS THEORY PRACT
[3]   ACCURACY AND DIMENSIONAL STABILITY OF 4 INTEROCCLUSAL RECORDING MATERIALS [J].
BALTHAZARHART, Y ;
SANDRIK, JL ;
MALONE, WFP ;
MAZUR, B ;
HART, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1981, 45 (06) :586-591
[4]   COMPRESSION RESISTANCE OF 4 INTEROCCLUSAL RECORDING MATERIALS [J].
BREEDING, LC ;
DIXON, DL .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06) :876-878
[5]  
CAMPOS AA, 1994, THESIS BOSTON U BOST
[6]  
Craig RG, 1989, RESTORATIVE DENT MAT
[7]   CLINICAL-EVALUATION OF THE ACCURACY OF INTEROCCLUSAL RECORDING MATERIALS [J].
FATTORE, L ;
MALONE, WF ;
SANDRIK, JL ;
MAZUR, B ;
HART, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (02) :152-157
[8]   PRINCIPLES FOR SELECTING INTEROCCLUSAL RECORDS FOR ARTICULATION OF DENTATE AND PARTIALLY DENTATE CASTS [J].
FREILICH, MA ;
ALTIERI, JV ;
WAHLE, JJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (02) :361-367
[9]   PROPERTIES OF INTEROCCLUSAL REGISTRATION MATERIALS [J].
LASSILA, V ;
MCCABE, JF .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01) :100-104
[10]   COMPARISON OF 5 INTEROCCLUSAL RECORDING MATERIALS [J].
LASSILA, V .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (02) :215-218