Smaller tidal volumes with room-air are not sufficient to ensure adequate oxygenation during bag-valve-mask ventilation

被引:59
作者
Dörges, V
Ocker, H
Hagelberg, S
Wenzel, V
Idris, AH
Schmucker, P
机构
[1] Univ Lubeck, Dept Anaesthesiol, D-23562 Lubeck, Germany
[2] Univ Innsbruck, Dept Anaesthesia & Intens Care Med, A-6020 Innsbruck, Austria
[3] Univ Florida, Coll Med, Dept Emergency Med, Gainesville, FL 32610 USA
关键词
self-inflatable bag; oxygenation; stomach inflation; apnoea; peak airway pressure; tidal volume; unprotected airway; cardiac arrest; cardiopulmonary resuscitation;
D O I
10.1016/S0300-9572(99)00161-6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The European Resuscitation Council has recommended decreasing tidal volume during basic life support ventilation from 800 to 1200 ml, as recommended by the American Heart Association, to 500 ml in order to minimise stomach inflation. However, if oxygen is not available at the scene of an emergency, and small tidal volumes are given during basic life support ventilation with a paediatric self-inflatable bag and room-air (21% oxygen), insufficient oxygenation and/or inadequate ventilation may result. When apnoea occurred after induction of anaesthesia, 40 patients were randomly allocated to room-air ventilation with either an adult (maximum volume, 1500 ml) or paediatric (maximum volume, 700 ml:) self-inflatable bag for 5 min before intubation. When using an adult (n = 20) versus paediatric (n = 20) self-inflatable bag, mean +/- SEM tidal volumes and tidal volumes per kilogram were significantly (P < 0.0001) larger (719 +/- 22 vs. 455 +/- 23 ml and 10.5 +/- 0.4 vs. 6.2 +/- 0.4 ml kg(-1), respectively). Compared with an adult self-inflatable bag, bag-valve-mask ventilation with room-air using a paediatric self-inflatable bag resulted in significantly (P < 0.01) lower paO(2) values (73 +/- 4 vs. 87 +/- 4 mmHg), but comparable carbon dioxide elimination (40 +/- 2 vs. 37 +/- 1 mmHg; NS). In conclusion, our results indicate that smaller tidal volumes of approximate to 6 ml kg(-1) (approximate to 500 ml) given with a paediatric self-inflatable bag and room-air maintain adequate carbon dioxide elimination, but do not result in sufficient oxygenation during bag-valve-mask ventilation. Thus, if small (16 ml kg(-1)) tidal volumes are being used during bag-valve-mask ventilation, additional oxygen is necessary. Accordingly, when additional oxygen during bag-valve-mask ventilation is not available, only large tidal volumes of approximate to 11 ml kg(-1) were able to maintain both sufficient oxygenation and carbon dioxide elimination. (C) 2000 Elsevier Science Ireland I,td. All rights reserved.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 21 条
[1]   Tidal volumes which are perceived to be adequate for resuscitation [J].
Baskett, P ;
Nolan, J ;
Parr, M .
RESUSCITATION, 1996, 31 (03) :231-234
[2]   Guidelines for the basic management of the airway and ventilation during resuscitation - A statement by the Airway and Ventilation Management Working Group of the European Resuscitation Council [J].
Baskett, PJF ;
Bossaert, L ;
Carli, P ;
Chamberlain, D ;
Dick, W ;
Nolan, JP ;
Parr, MJA ;
Scheidegger, D ;
Zideman, D ;
Blancke, W ;
Delooz, H ;
Handley, A ;
Kettler, D ;
Kloeck, W ;
Kramer, E ;
Quan, L ;
Studer, W ;
VanDrenth, A .
RESUSCITATION, 1996, 31 (03) :187-200
[3]  
BEGIN R, 1975, AM REV RESPIR DIS, V112, P879
[4]   LOWER ESOPHAGEAL SPHINCTER PRESSURE DURING PROLONGED CARDIAC-ARREST AND RESUSCITATION [J].
BOWMAN, FP ;
MENEGAZZI, JJ ;
CHECK, BD ;
DUCKETT, TM .
ANNALS OF EMERGENCY MEDICINE, 1995, 26 (02) :216-219
[5]  
DAVIES K, 1995, ACAD EMERG MED, V10, P855
[6]  
Dick WF, 1999, ANAESTHESIST, V48, P290, DOI 10.1007/s001010050704
[7]   Airway management during cardiopulmonary resuscitation - a comparative study of bag-valve-mask, laryngeal mask airway and combitube in a bench model [J].
Doerges, V ;
Sauer, C ;
Ocker, H ;
Wenzel, V ;
Schmucker, P .
RESUSCITATION, 1999, 41 (01) :63-69
[8]   Smaller tidal volumes during cardiopulmonary resuscitation: comparison of adult and paediatric self-inflatable bags with three different ventilatory devices [J].
Doerges, V ;
Sauer, C ;
Ocker, H ;
Wenzel, V ;
Schmucker, P .
RESUSCITATION, 1999, 43 (01) :31-37
[9]  
*EM CARD CAR COMM, 1992, JAMA-J AM MED ASSOC, V268, P2184
[10]  
IDRIS AH, 1999, CIRCULATION S1, V100, P644