Objectives: To examine the influence of in vivo hydrolysis on the physical properties of polyester grafts and their correlation to the period of implantation in the human body. Materials and methods: Sixty-five explanted vascular grafts were obtained after 0-23 years of implantation due to suture aneurysms (18), occlusion (12), graft infection (12), failure of graft material (7) and post-mortem (16). The surface was examined by scanning electron microscopy, the molecular integrity by infra-red spectroscopy and physical strength by probe puncture. Results: Scission of macromolecular chains and loss of strength were shown. It was demonstrated that hydrolytic degradation of polyester takes place with increasing time of implantation in humans. Analysis by linear regression showed that polyester grafts lose 31.4% of their bursting strength in 10 years and 100% in 15-39 years after implantation. Conclusions: Regular follow-ups of patients with aged vascular grafts and the precise documentation of implanted materials are necessary to estimate graft degradation.
引用
收藏
页码:540 / 548
页数:9
相关论文
共 21 条
[1]   PHYSICAL ASPECTS OF THE HYDROLYSIS OF POLYETHYLENE TEREPHTHALATE [J].
BALLARA, A ;
VERDU, J .
POLYMER DEGRADATION AND STABILITY, 1989, 26 (04) :361-374
[2]  
BERGER K, 1981, ANN SURG, V193, P477
[3]  
CLAGETT GP, 1983, SURGERY, V193, P699
[4]   ATTENUATED TOTAL REFLECTION - A NEW PRINCIPLE FOR THE PRODUCTION OF USEFUL INFRA-RED REFLECTION SPECTRA OF ORGANIC COMPOUNDS [J].
FAHRENFORT, J .
SPECTROCHIMICA ACTA, 1961, 17 (07) :698-+
[5]  
FRIEDMAN M, 1989, J CARDIOVASC SURG, V30, P136
[6]  
*INT ORG STAND, 1994, ISOCD71982 INT ORG S, P30
[7]  
KIM G-E, 1979, Archives of Surgery, V114, P1296
[8]   EVALUATING THE DIALINE(R) VASCULAR PROSTHESIS KNITTED FROM AN ALTERNATIVE SOURCE OF POLYESTER YARNS [J].
KING, MW ;
MAROIS, Y ;
GUIDOIN, R ;
UKPABI, P ;
DENG, XY ;
MARTIN, L ;
PARIS, E ;
DOUVILLE, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (05) :595-610
[9]  
KING MW, 1985, ASTM STP, V859, P294
[10]  
KOOPMANN MDE, 1980, J CARDIOVASC SURG, V21, P159