Electroanalysis of Bromate, iodate and chlorate at tungsten oxide modified platinum microelectrode arrays

被引:26
作者
Ordeig, Olga
Banks, Craig E.
Javier Del Campo, Fco.
Xavier Munoz, Francesc
Compton, Richard G.
机构
[1] CSIC, IMB, CNM, Inst Microelect Barcelona, Barcelona 08193, Spain
[2] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[3] Univ Autonoma Barcelona, IBB, E-08193 Barcelona, Spain
关键词
Bromate; iodate; chlorate; tungsten oxide; platinum Microelectrode Arrays;
D O I
10.1002/elan.200603570
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes the direct detection of Bromate, but also of chlorate and iodate, using modified arrays of platinum ultramicroelectrodes. The detection limits for these ions are IO3- = 0.76 mu M; BrO3- = 2.34 mu M and ClO3- = 133.2 mu M. The formation of a suitable tungsten oxide layer and the optimum analytical conditions are described. These oxide layers are formed electrochemically from hydrogen peroxide-tungstanate solutions in acid conditions. Although film stability may be an issue, particularly at pH > 3, these modified arrays of microelectrodes can be used for analytical purposes. After the analysis, the modifying oxide is easily removed and the Pt microelectrode array recovers its original properties. Finally, the detection limit is calculated using a propagation of errors approach which in the present context turned out more appropriate than IUPAC's 3 sigma.
引用
收藏
页码:1672 / 1680
页数:9
相关论文
共 37 条
[1]  
[Anonymous], 1998, ELECTROANAL
[2]  
[Anonymous], 1986, Federal Register
[3]   CHLORATE - A POTENT INHIBITOR OF PROTEIN SULFATION IN INTACT-CELLS [J].
BAEUERLE, PA ;
HUTTNER, WB .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1986, 141 (02) :870-877
[4]  
Bertotti M, 1998, QUIM NOVA, V21, P167
[5]   The electrochemical oxidation of organics using tungsten oxide based electrodes [J].
Bock, C ;
MacDougall, B .
ELECTROCHIMICA ACTA, 2002, 47 (20) :3361-3373
[6]   Bromate analysis in groundwater and wastewater samples [J].
Butler, R ;
Lytton, L ;
Godley, AR ;
Tothill, IE ;
Cartmell, E .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (10) :999-1006
[7]   Bromate environmental contamination: Review of impact and possible treatment [J].
Butler, R ;
Godley, A ;
Lytton, L ;
Cartmell, E .
CRITICAL REVIEWS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2005, 35 (03) :193-217
[8]   Electrochemical and spectroscopic characterization of a tungsten electrode as a sensitive amperometric sensor of small inorganic ions [J].
Casella, IG ;
Contursi, M .
ELECTROCHIMICA ACTA, 2005, 50 (20) :4146-4154
[9]   Determination of bromate in drinking waters by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Magnuson, ML ;
Pfaff, JD ;
Brockhoff, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :261-267
[10]   An analytical application of the electrocatalysis of the iodate reduction at tungsten oxide films [J].
da Rocha, JRC ;
Ferreira, TL ;
Torresi, RM ;
Bertotti, M .
TALANTA, 2006, 69 (01) :148-153