MALDI; TOFMS; plasma protein; biomaterial; biocompatible;
D O I
10.1016/S0142-9612(00)00054-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The analysis of plasma proteins adsorbed onto a polyurethane (PU) biomaterial was performed using matrix-assisted laser desorption/ionization time-of-fight mass spectrometry (MALDI-TOFMS). This article marks the first study on MALDI-TOFMS analysis of multiple proteins adsorbed from plasma, in vitro, onto the surface of a biomaterial to easily enable their characterization. Plasma standards from three different hosts were placed in contact with non-porous PU, a model biomaterial. Following the use of washing protocols developed in our laboratory, the biomaterial was analyzed, directly, with MALDI-TOFMS. Proteins with molecular weights (M-r) ranging from ca. 6.5 to 150 kDa were observed in the mass spectra and characterized upon comparison with proteins of known M-r. The proteins observed were tentatively identified as those known to adsorb onto PU, both in vitro and in vivo. In an attempt to model in vivo sorption, the PU biomaterial was exposed to freshly collected canine plasma, in vitro, for different lengths of lime. Corresponding MALDI-TOFMS spectra displayed increasing protein signal for a number of different proteins with increasing times of exposure to plasma. This method provided qualitative and semi-quantitative analysis of the proteins adsorbed onto the biomaterial surface. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1701 / 1710
页数:10
相关论文
共 47 条
[1]  
Anderson S. C., 1993, CLIN CHEM CONCEPTS A
[2]  
Andrade J.D., 1985, SURFACE INTERFACIAL
[3]  
BAIER RE, 1978, ARTIF ORGANS, V2, P422
[4]  
BELLISSIMO JA, 1984, T AM SOC ART INT ORG, V30, P359
[5]   POLYETHYLENE MEMBRANE AS A SAMPLE SUPPORT FOR DIRECT MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRIC ANALYSIS OF HIGH-MASS PROTEINS [J].
BLACKLEDGE, JA ;
ALEXANDER, AJ .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :843-848
[6]  
BRAYBROOK JH, 1997, BIOMATERIALS ENG SER
[7]   PROTEIN ADSORPTION TO POLY(ETHER URETHANE UREAS) MODIFIED WITH ACRYLATE AND METHACRYLATE POLYMER AND COPOLYMER ADDITIVES [J].
BRUNSTEDT, MR ;
ZIATS, NP ;
ROBERTSON, SP ;
HILTNER, A ;
ANDERSON, JM ;
LODOEN, GA ;
PAYET, CR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (03) :367-377
[8]   Direct profiling of proteins in biological tissue sections by MALDI mass spectrometry [J].
Chaurand, P ;
Stoeckli, M ;
Caprioli, RM .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5263-5270
[9]  
DAVIES J, 1994, NANOBIOLOGY, V3, P5
[10]  
DONG DE, 1983, POLYM PREPR-ACS, V24, P40