Three-dimensional automatic quantitative analysis of intravascular ultrasound images

被引:65
作者
Kovalski, G
Beyar, R
Shofti, R
Azhari, H [1 ]
机构
[1] Technion Israel Inst Technol, Dept Biomed Engn, IL-32000 Haifa, Israel
[2] Technion Israel Inst Technol, Fac Med, IL-32000 Haifa, Israel
关键词
IVUS; active contours; snakes; ultrasound; plaque;
D O I
10.1016/S0301-5629(99)00167-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Intravascular ultrasound (IVUS) has established itself as a useful tool for coronary assessment, The vast amount of data obtained by a single IVUS study renders manual analysis impractical for clinical use, A computerized method is needed to accelerate the process and eliminate user-dependency. In this study, a new algorithm is used to identify the lumen border and the media-adventitia border (the external elastic membrane). Setting an initial surface on the IVUS catheter perimeter and using active contour principles, the surface inflates until virtual force equilibrium defined by the surface geometry and image features is reached, The method extracts these features in three dimensions (3-D), Eight IVUS procedures were performed using an automatic pullback device. Using the ECG signal for synchronization, sets of images covering the entire studied region and corresponding to the same cardiac phase were sampled. Lumen and media-adventitia border contours were traced manually and compared to the automatic results obtained by the suggested method. Linear regression results for vessel area enclosed by the lumen and media-adventitia border indicate high correlation between manual vs, automatic tracings (y = 1.07 x -0.38; r = 0.98; SD = 0.112 mm(2); n = 88), These results indicate that the suggested algorithm may potentially provide a clinical tool for accurate lumen and plaque assessment. (C) 2000 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:527 / 537
页数:11
相关论文
共 16 条
[1]   INTRAVASCULAR ULTRASOUND IMAGING - A CURRENT PERSPECTIVE [J].
COY, KM ;
MAURER, G ;
SIEGEL, RJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (07) :1811-1823
[2]  
DIXON KJ, 1997, P 19 INT C IEEE EMBS
[3]  
GUNN SR, 1996, THESIS U SOUTHAMPTON
[4]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[5]  
LI W, 1992, IEEE P COMP CARD VEN, P353
[6]  
LI W, 1994, IEEE COMPUTERS CARDI, P277
[7]   Automatic segmentation of intravascular ultrasound images: A texture-based approach [J].
Mojsilovic, A ;
Popovic, M ;
Amodaj, N ;
Babic, R ;
Ostojic, M .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (06) :1059-1071
[8]  
SCHAWARZACHER SP, 1997, SEMIN INTERVENT CADI, V2, P1
[9]  
SCHMAUDER M, 1998, 8 MED C MED BIOL ENG, P91
[10]  
SONKA M, 1994, IEEE P COMP CARD BET, P281