Toxicological evaluation of exposed SPMD membranes

被引:10
作者
Kocí, V [1 ]
Mlejnek, M [1 ]
Kochánková, L [1 ]
机构
[1] ICT, Dept Environm Chem, Prague 16628, Czech Republic
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2003年 / 1卷 / 01期
关键词
passive sampling; POPs; SPMD; toxicity testing; Vtox;
D O I
10.2478/BF02479255
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article is focused on bioassay evaluation of exposed SPMDs. Toxicity testing of SPMD extract is a suitable complementary parameter to chemical analysis. Vtox as an integrative parameter describing toxic properties of extract from membrane and thus a level of contamination of assessed ambient is presented here. Two examples of practical use of Vtox is demonstrated: a course of toxicity throw wastewater treatment plant with industrial inlets and increase of toxicity in surface water body caused by leakages of POPs from industrial plant. (C) Central European Science Journals. All rights reserved.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 12 条
[1]   Determination of uptake kinetics (Sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water [J].
Huckins, JN ;
Petty, JD ;
Orazio, CE ;
Lebo, JA ;
Clark, RC ;
Gibson, VL ;
Gala, WR ;
Echols, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (21) :3918-3923
[2]   LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
HUCKINS, JN ;
MANUWEERA, GK ;
PETTY, JD ;
MACKAY, D ;
LEBO, JA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) :2489-2496
[3]  
HUCKINS JN, 2000, GUIDE USE SEMIPERMEA
[4]  
Johnson BT, 2000, ENVIRON TOXICOL, V15, P248, DOI 10.1002/1522-7278(2000)15:3<248::AID-TOX10>3.3.CO
[5]  
2-H
[6]  
KOCI V, 2002, CZECH PHYCOLOGY, V2, P129
[7]   Passive sampling for long-term monitoring of organic pollutants in water [J].
Kot, A ;
Zabiegala, B ;
Namiesnik, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (07) :446-459
[8]   Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants [J].
Petty, JD ;
Orazio, CE ;
Huckins, JN ;
Gale, RW ;
Lebo, JA ;
Meadows, JC ;
Echols, KR ;
Cranor, WL .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) :83-95
[9]   An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests [J].
Petty, JD ;
Jones, SB ;
Huckins, JN ;
Cranor, WL ;
Parris, JT ;
McTague, TB ;
Boyle, TP .
CHEMOSPHERE, 2000, 41 (03) :311-321
[10]   Toxicological investigation of soils with the solid-phase flash assay:: Comparison with other ecotoxicological tests [J].
Pollumaa, L ;
Kahru, A ;
Eisenträger, A ;
Reiman, R ;
Maloveryan, A ;
Rätsep, A .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2000, 28 (03) :461-472