Protein A immobilized monolithic capillary column for affinity chromatography

被引:77
作者
Pan, ZF
Zou, HF
Mo, WM
Huang, XD
Wu, RN
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116011, Peoples R China
[2] Zhejiang Univ Technol, Coll Chem Engn, Zheijang 310014, Peoples R China
基金
中国国家自然科学基金;
关键词
affinity chromatography; monolithic rod; capillary column; protein A; hIgG;
D O I
10.1016/S0003-2670(02)00511-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monolithic capillary columns for affinity chromatography were prepared by an in situ polymerization procedure using glycidyl methacrylate (GMA) as a monomer and trimethylolpropane trimethacrylate (TRIM) and ethylene dimethacrylate (EDMA) as cross-linkers, respectively. Scanning electron microscopy was applied to characterize the morphology of the end of monolithic capillary and mercury intrusion porosimetry to characterize the polymer rod prepared within the confines of a stainless steel column with 50 mm x 4.6 mm i.d. under the same polymerization condition. Obvious differences in the porous properties between the TRIM- and EDMA-based monoliths could be observed. Moreover, the mechanical stability of these two monolithic capillary columns was compared by testing the reproducibility of the column performance. The rod prepared with GMA and TRIM proved to be mechanically more stable than that prepared with GMA and EDMA. Protein A was immobilized on the monolithic rod for affinity chromatography and the experiments were performed on a capillary electrophoresis instrument, using its pressure system as the driving force. Non-specific adsorption was not observed on the TRIM-based affinity column, as proved with bovine serum albumin (BSA) as a test protein. The affinity column prepared with GMA and TRIM was then applied to determine the hIgG concentration in human serum. The correlative coefficient of the calibration curve reached 0.9942. The amount of adsorbed hIgG was unaffected by the flow rate of the loading buffer, which makes this method suitable for fast determination of biomacromolecules in microliter samples. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 34 条
  • [1] Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay
    Andersson, LI
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01): : 163 - 173
  • [2] Molecular imprinting: developments and applications in the analytical chemistry field
    Andersson, LI
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (01): : 3 - 13
  • [3] Comparison of antibody binding to immobilized group specific affinity ligands in high performance monolith affinity chromatography
    Berruex, LG
    Freitag, R
    Tennikova, TB
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 24 (01) : 95 - 104
  • [4] Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
  • [5] Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds
    Ericson, C
    Liao, JL
    Nakazato, K
    Hjerten, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 33 - 41
  • [6] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON CONTINUOUS POLYMER BEDS
    HJERTEN, S
    LIAO, JL
    ZHANG, R
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 473 (01): : 273 - 275
  • [7] Iberer G, 1999, LC GC N AM, V17, P998
  • [8] Monoliths as stationary phases for separation of proteins and polynucleotides and enzymatic conversion
    Josic, D
    Buchacher, A
    Jungbauer, A
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 752 (02): : 191 - 205
  • [9] Continuous beds for microchromatography:: Chromatofocusing and anion exchange chromatography
    Li, YM
    Liao, JL
    Zhang, R
    Henriksson, H
    Hjertén, S
    [J]. ANALYTICAL BIOCHEMISTRY, 1999, 267 (01) : 121 - 124
  • [10] CONTINUOUS BEDS FOR MICROCHROMATOGRAPHY - CATION-EXCHANGE CHROMATOGRAPHY
    LI, YM
    LIAO, JL
    NAKAZATO, K
    MOHAMMAD, J
    TERENIUS, L
    HJERTEN, S
    [J]. ANALYTICAL BIOCHEMISTRY, 1994, 223 (01) : 153 - 158