Fuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia

被引:23
作者
Curatolo, M [1 ]
Derighetti, M [1 ]
PetersenFelix, S [1 ]
Feigenwinter, P [1 ]
Fischer, M [1 ]
Zbinden, AM [1 ]
机构
[1] SWISS FED INST TECHNOL,AUTOMAT CONTROL LAB,ZURICH,SWITZERLAND
关键词
anaesthetic techniques; low flow; anaesthetics volatile; isoflurane; computers; model; computer simulation;
D O I
10.1093/bja/76.2.245
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In order to evaluate the performance of feedback fuzzy logic control of inspired oxygen and isoflurane concentrations, we studied 30 patients undergoing discectomy for lumbar (n = 26) or cervical (n = 4) disc herniation. Patients were allocated random to one of two groups: a standard group (n = 15) with low flow anaesthesia (1.2-1.3 litre min(-1)) and manual control of gas concentrations; and a fuzzy group (n = 15) with minimal flow (0.5 litre min(-1)) and fuzzy logic feedback control of gas concentrations. Fuzzy logic control achieved and maintained very accurately the desired isoflurane concentration. Oxygen concentration was controlled more precisely than in the standard group. Delivery and costs of oxygen and nitrous oxide were significantly lower in the fuzzy group (P < 0.01). Accumulation of foreign gases was observed in one patient during low flow and in 11 patients during minimal flow anaesthesia. In conclusion, fuzzy logic control of inspired oxygen and isoflurane concentration during minimal flow anaesthesia was reliable and reduced anaesthetic gas delivery and costs.
引用
收藏
页码:245 / 250
页数:6
相关论文
共 17 条
[1]  
ASBURY AJ, 1995, BRIT J ANAESTH, V75, P1
[2]   COMPARISON OF COSTS OF DIFFERENT ANESTHETIC TECHNIQUES [J].
BENGTSON, JP ;
SONANDER, H ;
STENQVIST, O .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1988, 32 (01) :33-35
[3]  
Bezdek J. E., 1993, IEEE Transactions on Fuzzy Systems, V1, P1, DOI 10.1109/TFUZZ.1993.6027269
[4]   EFFECTS OF DRY ANESTHETIC GASES ON TRACHEOBRONCHIAL CILIATED EPITHELIUM [J].
CHALON, J ;
MALEBRANCHE, J ;
LOEW, DAY .
ANESTHESIOLOGY, 1972, 37 (03) :338-+
[5]  
DALE O, 1991, ACTA ANAESTHESIO S96, V35, P40
[6]   LOW-FLOW ANESTHESIA REDUCES OCCUPATIONAL EXPOSURE TO INHALATION ANESTHETICS - ENVIRONMENTAL AND BIOLOGICAL MEASUREMENTS IN OPERATING-ROOM PERSONNEL [J].
IMBERTI, R ;
PRESEGLIO, I ;
IMBRIANI, M ;
GHITTORI, S ;
CIMINO, F ;
MAPELLI, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (05) :586-591
[7]   FUZZY CONTROL IN ANESTHESIA [J].
MARTIN, JF .
JOURNAL OF CLINICAL MONITORING, 1994, 10 (02) :77-80
[8]  
MORITA S, 1985, ANESTH ANALG, V64, P343
[9]   CONTROLLED ANESTHESIA - A CLINICAL-EVALUATION OF AN APPROACH USING PATIENT CHARACTERISTICS IDENTIFIED DURING UPTAKE [J].
MORRIS, P ;
TATNALL, ML ;
MONTGOMERY, FJ .
BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (11) :1065-1075
[10]  
ROLLY G, 1994, ANESTH ANALG, V79, P545