Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

被引:12
作者
Kumar, A. J. Shyam [1 ]
Parmar, V. [1 ]
Bankart, J. [1 ]
Williams, S. C. [1 ]
Harper, W. M. [1 ]
机构
[1] Univ Leicester, Glenfield Hosp, Dept Orthopaed, Leicester LE3 9QP, Leics, England
关键词
D O I
10.1007/s00264-006-0092-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducted by two independent observers, and the radiographs were calibrated to correct for magnification. Accuracy of lag screw placement was determined by "tip apex distance," described by Baumgaertner et al., and by the ratio method described by Parker. The mean tip apex distance was 24.0 mm in sliding hip screw plate systems and 21.1 mm in cephalocondylic nails. This was found to be statistically significant. Lag screw placement through cephalocondylic nails is more accurate and therefore has less chance of cut-out compared with sliding hip screw plate systems. There was no statistically significant difference using Parker's ratio method because this method quantifies the direction of the screw rather than the depth of penetration.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 5 条
[1]
Implant-related complications in the treatment of unstable intertrochanteric fractures:: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices [J].
Audigé, L ;
Hanson, B ;
Swiontkowski, MF .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (04) :197-203
[2]
THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[3]
Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail [J].
Kawaguchi, S ;
Sawada, K ;
Nabeta, Y .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01) :47-53
[4]
CUTTING-OUT OF THE DYNAMIC HIP SCREW RELATED TO ITS POSITION [J].
PARKER, MJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04) :625-625
[5]
Prediction of fixation failure after sliding hip screw fixation [J].
Pervez, H ;
Parker, MJ ;
Vowler, S .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (10) :994-998