Degradation of mechanical behavior in UHMWPE after natural and accelerated aging

被引:106
作者
Edidin, AA
Jewett, CW
Kalinowski, A
Kwarteng, K
Kurtz, SM
机构
[1] Stryker Howmedica Osteon, Allendale, NJ 07401 USA
[2] Exponent Failure Anal Associates, Philadelphia, PA 19103 USA
关键词
ultra-high molecular weight polyethylene; UHMWPE; mechanical behavior; oxidation; degradation;
D O I
10.1016/S0142-9612(00)00021-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultra-high molecular weight polyethylene (UHMWPE) is known to degrade during natural (shelf) aging following gamma irradiation in air, but the mechanical signature of degradation remains poorly understood. Accelerated aging methods have been developed to reproduce the natural aging process as well as to precondition total joint replacement components prior to joint simulator wear testing. In this study, we compared the mechanical behavior of naturally (shelf) aged and accelerated aged tibial inserts using a previously validated miniature specimen testing technique known as the small punch test. Tibial inserts made of GUR 1120 and sterilized with 25 to 40 kGy of gamma radiation (in air) in 1988, 1993, and 1997 were obtained; a subset of the 1997 implants were subjected to 4 weeks of accelerated aging in air at 80 degrees C. To determine the spatial variation of mechanical properties within each insert, miniature disk shaped specimens were machined from the surface and subsurface regions of the inserts. Analysis of variance of the test data showed that aging significantly affected the small punch test measures of elastic modulus, initial load, ultimate load, ultimate displacement, and work to failure. The accelerated aging protocol was unable to reproduce the spatial mechanical profile seen in shelf aged components, but it did mechanically degrade the surface of GUR 1120 tibial components to an extent comparable to that seen after 10 years of natural aging. Test specimens showed a fracture morphology consistent with the decreased ductility and toughness which was corroborated by the small punch test metrics of this study. Our data support the hypothesis that UHMWPE undergoes a spatially nonuniform change towards a less ductile (more brittle) mechanical behavior after gamma irradiation in air and shelf aging. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1451 / 1460
页数:10
相关论文
共 40 条
[1]  
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.0.CO
[2]  
2-A
[3]   RADIATION-INDUCED CRYSTALLINITY CHANGES IN LINEAR POLYETHYLENE - LONG-TERM AGING EFFECTS IN PRESSURE-CRYSTALLIZED ULTRA-HIGH-MOLECULAR-WEIGHT POLYMER [J].
BHATEJA, SK ;
YARBROUGH, SM ;
ANDREWS, EH .
JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS, 1990, B29 (01) :1-10
[4]   RADIATION-INDUCED CRYSTALLINITY CHANGES IN LINEAR POLYETHYLENE - INFLUENCE OF AGING [J].
BHATEJA, SK .
JOURNAL OF APPLIED POLYMER SCIENCE, 1983, 28 (02) :861-872
[5]   RADIATION-INDUCED CRYSTALLINITY CHANGES IN POLYETHYLENE BLENDS [J].
BHATEJA, SK ;
ANDREWS, EH .
JOURNAL OF MATERIALS SCIENCE, 1985, 20 (08) :2839-2845
[6]  
BOSTROM MP, 1994, CLIN ORTHOPAEDICS, V309, P20
[7]  
Collier JP, 1998, ORTHOPEDICS, V21, P865
[8]  
DIMAIO WG, 1998, M T 44 ORTH RES SOC
[9]   Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement [J].
Edidin, AA ;
Pruitt, L ;
Jewett, CW ;
Crane, DJ ;
Roberts, D ;
Kurtz, SM .
JOURNAL OF ARTHROPLASTY, 1999, 14 (05) :616-627
[10]  
EDIDIN AA, 2000, IN PRESS J ARHTROPLA, V15