Differentiation of heroin and cocaine using dual-energy CT-an experimental study

被引:13
作者
Grimm, Jochen [1 ,2 ,3 ,4 ]
Wudy, Ramona [1 ]
Ziegeler, Edvard [1 ]
Wirth, Stefan [1 ]
Uhl, Michael [5 ]
Reiser, Maximilian F. [1 ]
Scherr, Michael [1 ]
机构
[1] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, D-80336 Munich, Germany
[2] Univ Lausanne Hosp, Dept Med Radiol, CH-1011 Lausanne, Switzerland
[3] Univ Lausanne, CH-1011 Lausanne, Switzerland
[4] Ctr Legal Med Lausanne & Geneva, CH-1011 Lausanne, Switzerland
[5] Bavarian State Criminal Police Off, D-80636 Munich, Germany
关键词
Body packing; Dual-energy CT; Dual-energy index; Material differentiation; Illicit drugs; DOSE COMPUTED-TOMOGRAPHY; BODY-PACKING; PACKERS; RADIOGRAPHY; STUFFERS; PUSHERS; SURGERY; DRUGS;
D O I
10.1007/s00414-014-0980-6
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
030101 [法学理论]; 030111 [法律史学]; 100218 [急诊医学];
摘要
To evaluate if heroin and cocaine can be distinguished using dual-energy CT. Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 35 条
[1]
Beer SA., 2008, WORLD J SURG, V32, P281, DOI DOI 10.1007/S00268-007-9316-8
[2]
Packers, pushers and stuffers-managing patients with concealed drugs in UK emergency departments: a clinical and medicolegal review [J].
Booker, R. J. ;
Smith, J. E. ;
Rodger, M. P. .
EMERGENCY MEDICINE JOURNAL, 2009, 26 (05) :316-320
[3]
Brogdon BG, 2010, BROGDONS FORENSIC RA, P297, DOI [10.1201/b10323-26, DOI 10.1201/B10323-26]
[4]
Bulstrode N, 2002, ANN ROY COLL SURG, V84, P35
[5]
Claffey M, 2002, NEW YORK DAILY NEWS, P1
[6]
Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging? [J].
Coursey, Courtney A. ;
Nelson, Rendon C. ;
Boll, Daniel T. ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Neville, Amy M. ;
Marin, Daniele ;
Gupta, Rajan T. ;
Schindera, Sebastian T. .
RADIOGRAPHICS, 2010, 30 (04) :1037-1055
[7]
Body packers: a plea for conservative treatment [J].
de Bakker, Jacob K. ;
Nanayakkara, P. W. B. ;
Geeraedts, L. M. G., Jr. ;
de Lange, E. S. M. ;
Mackintosh, M. O. ;
Bonjer, H. J. .
LANGENBECKS ARCHIVES OF SURGERY, 2012, 397 (01) :125-130
[8]
East JM, 2005, W INDIAN MED J, V54, P38
[9]
"Drug mules" as a radiological challenge: Sensitivity and specificity in identifying internal cocaine in body packers, body pushers and body stuffers by computed tomography, plain radiography and Lodox [J].
Flach, Patricia M. ;
Ross, Steffen G. ;
Ampanozi, Garyfalia ;
Ebert, Lars ;
Germerott, Tanja ;
Hatch, Gary M. ;
Thali, Michael J. ;
Patak, Michael A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2518-2526
[10]
The risky business of body packers and body stuffers [J].
Goertemoeller, Sheila ;
Behrman, Alysha .
JOURNAL OF EMERGENCY NURSING, 2006, 32 (06) :541-544