Modelling of a new solar air heater through least-squares support vector machines

被引:204
作者
Esen, Hikmet [1 ]
Ozgen, Filiz [1 ]
Esen, Mehmet [1 ]
Sengur, Abdulkadir [2 ]
机构
[1] Firat Univ, Fac Tech Educ, Dept Mech Educ, TR-23119 Elazig, Turkey
[2] Firat Univ, Fac Tech Educ, Dept Elect & Comp Sci, TR-23119 Elazig, Turkey
关键词
Solar air heater; Least-squares support vector machine; Predict; Efficiency; Kernel; ARTIFICIAL NEURAL-NETWORKS; COLLECTOR EFFICIENCY; FLAT-PLATE; ABSORBER PLATE; ENERGY-SYSTEMS; FLOW; PERFORMANCE; CLASSIFIERS; REGRESSION; TUTORIAL;
D O I
10.1016/j.eswa.2009.02.045
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper reports on a modelling study of new solar air heater (SAH) system efficiency by using leastsquares support vector machine (LS-SVM) method. In this study, a device for inserting an absorbing plate made of aluminium cans into the double-pass channel in a flat-plate SAH. A SAH system is a multi-variable system that is hard to model by conventional methods. As regards the LS-SVM, it has a superior capability for generalization, and this capability is independent on the dimensionality of the input data. In this study, a LS-SVM based method was intended to adopt SAH system for efficient modelling. For modelling, different mass flow rates in flow duct and collector types are used and then for obtaining the optimum LS-SVM parameters, such as regularization parameter, and optimum kernel function and parameters, several tests have been carried out. The performance of the proposed methodology was evaluated by using several statistical validation parameters. It is found that root mean squared error (RMSE) value is 0.0024, the coefficient of multiple determinations (R(2)) value is 0.9997 and coefficient of variation (cov) value is 2.1194 for the proposed radial basis function (RBF)-kernel LS-SVM method at 0.03 kg/s air mass flow rate. It is found that RMSE value is 0.0135, R(2) value is 0.9991 and cov value is 2.9868 for the proposed RBF-kernel LS-SVM method at 0.05 kg/s air mass flow rate. Comparison between predicted and experimental results indicates that the proposed LS-SVM model can be used for estimating the efficiency of SAHs with reasonable accuracy. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:10673 / 10682
页数:10
相关论文
共 33 条
[1]  
Albizzati E., 2000, P MILL SOL FOR 2000, P663
[2]   Thermal performance of an air solar collector with an absorber plate made of recyclable aluminum cans [J].
Alvarez, G ;
Arce, J ;
Lira, L ;
Heras, MR .
SOLAR ENERGY, 2004, 77 (01) :107-113
[3]   Applicational aspects of support vector machines [J].
Belousov, AI ;
Verzakov, SA ;
von Frese, J .
JOURNAL OF CHEMOMETRICS, 2002, 16 (8-10) :482-489
[4]   A tutorial on Support Vector Machines for pattern recognition [J].
Burges, CJC .
DATA MINING AND KNOWLEDGE DISCOVERY, 1998, 2 (02) :121-167
[5]   On the modelling of nonlinear dynamic systems using support vector neural networks [J].
Chan, WC ;
Chan, CW ;
Cheung, KC ;
Harris, CJ .
ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2001, 14 (02) :105-113
[6]  
Drezet PML, 1998, UKACC INTERNATIONAL CONFERENCE ON CONTROL '98, VOLS I&II, P688, DOI 10.1049/cp:19980312
[7]   Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates [J].
Esen, Hikmet .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1046-1054
[8]   Using support vector regression for the prediction of the band gap and melting point of binary and ternary compound semiconductors [J].
Gu, TH ;
Lu, WC ;
Bao, XH ;
Chen, NY .
SOLID STATE SCIENCES, 2006, 8 (02) :129-136
[9]  
HARRIS CJ, 1999, SOFT COMPUTING INTEL, P377
[10]   Performance of flat plate solar air heaters with optimum channel geometry for constant/variable flow operation [J].
Hegazy, AA .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (04) :401-417