Sagittal Laxity After Posterior Cruciate Ligament-Retaining Mobile-Bearing Total Knee Arthroplasty

被引:14
作者
Chouteau, Julien [1 ,2 ,3 ,4 ,5 ]
Lerat, Jean Luc [1 ]
Testa, Rodolph [1 ,2 ,3 ,4 ]
Moyen, Bernard [1 ,2 ,3 ,4 ]
Scott, Banks A. [5 ]
机构
[1] Ctr Hosp Lyon Sud, Serv Chirurg Orthoped Traumatol & Med Sport, F-69495 Pierre Benite, France
[2] Univ Lyon 1, F-69003 Lyon, France
[3] Inst Natl Rech Transports & Leur, F-69675 Bron, France
[4] Fac Med Lyon Sud, Lab Biomecan & Mecan Chocs, UMR T 9406, Oullins, France
[5] Univ Florida, Orthopaed Biomech Lab, Gainesville, FL USA
关键词
sagittal laxity; posterior cruciate ligament retaining; total knee arthroplasty; radiographic drawer; INSTABILITY; KINEMATICS;
D O I
10.1016/j.arth.2008.05.028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Posterior cruciate ligament stretching after posterior cruciate ligament-retaining (CR) total knee arthroplasty (TKA) can lead to an increase in sagittal laxity, knee dysfunction, or accelerated damage to the tibial bearing surface. We conducted a prospective study on 74 consecutive mobile-bearing CR TKA to determine if knee laxity changed with time or if knees with large initial laxity experienced greater increases in laxity. Patients were studied With radiographic posterior and anterior drawer examinations at 3 and 23 months. Model-based shape-matching techniques were used to measure TKA kinematics. We found a 1-mm increase in posterior drawer. Knees with large postoperative drawers did not exhibit increased laxity at last follow-up. The use of a mobile-bearing CR TKA did not significantly modify the midterm knee sagittal laxity.
引用
收藏
页码:710 / 715
页数:6
相关论文
共 25 条
[1]
THE INFLUENCE OF TOTAL KNEE-REPLACEMENT DESIGN ON WALKING AND STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
FERMIER, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1328-1335
[2]
Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[3]
Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[4]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[5]
Effects of radiograph projection parameter uncertainty on TKA kinematics from model-image registration [J].
Chouteau, J. ;
Lerat, J. L. ;
Testa, R. ;
Moyen, B. ;
Banks, S. A. .
JOURNAL OF BIOMECHANICS, 2007, 40 (16) :3744-3747
[6]
The PCL significantly affects the functional outcome of total knee arthroplasty [J].
Conditt, MA ;
Noble, PC ;
Bertolusso, R ;
Woody, J ;
Parsley, BS .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :107-112
[7]
Dejour D, 1999, CLIN ORTHOP RELAT R, P182
[8]
DORR LD, 1988, CLIN ORTHOP RELAT R, P36
[9]
Measurement of anterior-posterior knee laxity: a comparison of three techniques [J].
Fleming, BC ;
Brattbakk, B ;
Peura, GD ;
Badger, GJ ;
Beynnon, BD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (03) :421-426
[10]
Sagittal laxity in vivo after total knee arthroplasty [J].
Ishii, Y ;
Matsuda, Y ;
Ishii, R ;
Sakata, S ;
Omori, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (04) :249-253