Fetal venous circulation - an update on hemodynamics

被引:41
作者
Kiserud, T [1 ]
机构
[1] Bergen Univ Hosp, Dept Obstet & Gynecol, Unit Fetal Med, N-5021 Bergen, Norway
关键词
blood flow; circulation; compliance; Doppler; echocardiography; fetus; impedance; liver; ultrasound; vein;
D O I
10.1515/JPM.2000.011
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The refinements of modern ultrasound techniques permit a renewed examination of old concepts of fetal circulation. The concept of preferential streaming of umbilical blood through the foramen ovale is verified by animal experiments, and ultrasound studies have confirmed that a similar mechanism operates in human fetuses. However, the normalized umbilical flow appears to be less in the human than in fetal sheep, and decreases with advancing gestational age (115 ml min(-1) kg(-1) at 20 and 64 mL min(-1) kg(-1) at 40 weeks). Compared to the 50% shunting of umbilical blood through the ductus venosus found in animal experiments, the degree of shunting in the human fetus under physiological conditions is considerably less, 30% at 20 weeks, which decreases to 18% at 32 weeks, suggesting a higher priority of the fetal liver than previously realized. Augmented pulsatility in the precordial veins, ductus venosus, and umbilical vein is an important clinical sign that is poorly understood. Recent fluid dynamic studies show that, apart from the pressure generated in the atria, it is the stiffness of the vessel wall, compliance, and notably, impedance which modify these waves. Particularly the substantial shift in impedance at the ductus venosus-umbilical vein junction causes wave reflection and reduced transmission of waves, the result being diminished or absent pulsation in the umbilical vein.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 43 条
[1]  
BARCLAY DM, 1942, BRIT J RADIOL, V15, P249
[2]  
BARCLAY DM, 1944, FOETAL CIRCULATION C
[3]   DISTRIBUTION OF CIRCULATION IN NORMAL AND ASPHYXIATED FETAL PRIMATE [J].
BEHRMAN, RE ;
LEES, MH ;
PETERSON, EN ;
DELANNOY, CW ;
SEEDS, AE .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1970, 108 (06) :956-&
[4]   Abnormal ductus venosus blood flow in trisomy 21 fetuses during early pregnancy [J].
Borrell, A ;
Antolin, E ;
Costa, D ;
Farre, MT ;
Martinez, JM ;
Fortuny, A .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (06) :1612-1617
[5]   The effect of intravascular blood transfusion on the flow velocity waveform of the portal venous system of the anemic fetus [J].
d'Ancona, RL ;
Rahman, F ;
Ozcan, T ;
Copel, JA ;
Mari, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (05) :333-337
[6]  
Dawes G. S., 1968, Foetal and neonatal physiology: A comparative study of the changes at birth
[7]   DUCTUS VENOSUS INDEX - A METHOD FOR EVALUATING RIGHT-VENTRICULAR PRELOAD IN THE 2ND-TRIMESTER FETUS [J].
DEVORE, GR ;
HORENSTEIN, J .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1993, 3 (05) :338-342
[8]  
EDELSTONE D I, 1980, Journal of Developmental Physiology (Eynsham), V2, P219
[9]   LIVER AND DUCTUS VENOSUS BLOOD FLOWS IN FETAL LAMBS IN UTERO [J].
EDELSTONE, DI ;
RUDOLPH, AM ;
HEYMANN, MA .
CIRCULATION RESEARCH, 1978, 42 (03) :426-433
[10]   EFFECTS OF HYPOXEMIA AND DECREASING UMBILICAL FLOW ON LIVER AND DUCTUS VENOSUS BLOOD FLOWS IN FETAL LAMBS [J].
EDELSTONE, DI ;
RUDOLPH, AM ;
HEYMANN, MA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (05) :H656-H663