An in vivo investigation of the rabbit skin responses to transdermal iontophoresis

被引:19
作者
Anigbogu, A
Patil, S
Singh, P
Liu, P
Dinh, S
Maibach, H [1 ]
机构
[1] Univ Calif San Francisco, Dept Dermatol, San Francisco, CA 94143 USA
[2] Novartis Pharmaceut, Pharmaceut Dev, E Hanover, NJ 07936 USA
关键词
iontophoresis; skin; irritation; erythema; transepidermal water loss; laser Doppler velocimetry;
D O I
10.1016/S0378-5173(00)00371-9
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To optimize the benefits of transdermal iontophoresis, it is necessary to develop a suitable animal model that would allow for extensive assessments of the biological effects associated with electro-transport. Rabbit skin responses to iontophoresis treatments were evaluated by visual scoring and by non-invasive bioengineering parameters and compared with available human data. In the current density range 0.1 1.0 mA/cm(2) applied for 1 h using 0.9% w/v NaCl and 0.5 mA/cm(2) for up to 4 h, no significant irritation was observed. 2 mA/cm(2) applied through an area of 1 cm(2) for 1 h resulted in slight erythema at both active electrode sites but without significant changes in transepidermal water loss (TEWL) and laser Doppler velocimetry (LDV). A value of 4 mA/cm(2) under similar conditions caused moderate erythema at the anode and cathode with TEWL and LDV bring significantly elevated at both sites; 1 mA\cm(2) current applied for 4 h, caused moderate erythema at both anode and cathode; and 1 mA/cm(2) applied for 1 h caused no irritation when the area of exposure was increased from 1 to 4.5 cm(2). When significant irritation and barrier impairment occurred, the erythema was resolved within 24 h with barrier recovery complete 3-5 days post-treatment. Rabbit skin thus shows promise as an acceptable model for iontophoresis experiments. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:195 / 206
页数:12
相关论文
共 43 条
[1]   IONTOPHORETIC DELIVERY OF DRUGS - FUNDAMENTALS, DEVELOPMENTS AND BIOMEDICAL APPLICATIONS [J].
BANGA, AK ;
CHIEN, YW .
JOURNAL OF CONTROLLED RELEASE, 1988, 7 (01) :1-24
[2]   NONINVASIVE BIOENGINEERING ASSESSMENT OF PSORIASIS [J].
BERARDESCA, E ;
MAIBACH, HI .
INTERNATIONAL JOURNAL OF DERMATOLOGY, 1989, 28 (03) :157-160
[3]  
BERNARDI L, 1995, BIOENGINEERING SKIN, P13
[4]   GUIDELINES FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY - A REPORT FROM THE STANDARDIZATION GROUP OF THE EUROPEAN-SOCIETY-OF-CONTACT-DERMATITIS [J].
BIRCHER, A ;
DEBOER, EM ;
AGNER, T ;
WAHLBERG, JE ;
SERUP, J .
CONTACT DERMATITIS, 1994, 30 (02) :65-72
[5]  
BRAIN SD, 1989, PHARM SKIN, V1, P409
[6]   Acute effects of iontophoresis on human skin in vivo: Cutaneous blood flow and transepidermal water loss measurements [J].
Brand, RM ;
Singh, P ;
AspeCarranza, E ;
Maibach, HI ;
Guy, RH .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 1997, 43 (02) :133-138
[7]   CHARACTERIZATION OF THE PORE TRANSPORT-PROPERTIES AND TISSUE ALTERATION OF EXCISED HUMAN-SKIN DURING IONTOPHORESIS [J].
BURNETTE, RR ;
ONGPIPATTANAKUL, B .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1988, 77 (02) :132-137
[8]   CHARACTERIZATION OF THE PERMSELECTIVE PROPERTIES OF EXCISED HUMAN-SKIN DURING IONTOPHORESIS [J].
BURNETTE, RR ;
ONGPIPATTANAKUL, B .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (10) :765-773
[9]   The effect of saline iontophoresis on skin integrity in human volunteers .1. Methodology and reproducibility [J].
Camel, E ;
OConnell, M ;
Sage, B ;
Gross, M ;
Maibach, H .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1996, 32 (02) :168-178
[10]   IONTOPHORESIS OF A MODEL PEPTIDE ACROSS HUMAN SKIN IN-VITRO - EFFECTS OF IONTOPHORESIS PROTOCOL, PH, AND IONIC-STRENGTH ON PEPTIDE FLUX AND SKIN IMPEDANCE [J].
CRAANEVANHINSBERG, WHM ;
BAX, L ;
FLINTERMAN, NHM ;
VERHOEF, J ;
JUNGINGER, HE ;
BODDE, HE .
PHARMACEUTICAL RESEARCH, 1994, 11 (09) :1296-1300