Nonparametric mass calibration using hundreds of internal calibrants

被引:11
作者
Becker, Christopher H. [1 ]
Kumar, Praveen [1 ]
Jones, Ted [1 ]
Lin, Hua [1 ]
机构
[1] PPD Inc, Menlo Pk, CA 94025 USA
关键词
D O I
10.1021/ac061359u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In situations where many molecular ions (> 100) can be identified to the level of their elemental composition, such as in proteomics, metabolomics, and glycomics, a final mass calibration is possible for every sample without reliance on any analytical description of instrument behavior. This is achieved by applying a nonparametric calibration curve determined from the difference in observed, centroided m/z values of the known, internal calibrant molecular ions versus that calculated from their elemental compositions, over the m/z range. In examples here, proteomic data are examined for two sets of samples of complex mixtures composed of tryptic peptides from human and mouse blood proteins using high-resolution time-of-flight mass spectra from on-line liquid chromatography-mass spectrometry experiments. Resultant, postcalibration median absolute value mass errors and root-mean-square errors for peptides between 300 and 1100 m/z for many samples ranged from 3.1 to 4.4 and 5.2 to 6.9 ppm, respectively. The method may be applied to other types of mass spectrometers.
引用
收藏
页码:1702 / 1707
页数:6
相关论文
共 22 条
[1]   Quantifying reproducibility for differential proteomics: noise analysis for protein liquid chromatography-mass spectrometry of human serum [J].
Anderle, M ;
Roy, S ;
Lin, H ;
Becker, C ;
Joho, K .
BIOINFORMATICS, 2004, 20 (18) :3575-3582
[2]  
[Anonymous], 2006, a language and environment for statistical computing
[3]   Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer [J].
Blom, KF .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :715-719
[4]  
COTTER RJ, 1997, TIME OF FLIGHT MASS
[5]   Improvements in protein identification by MALDI-TOF-MS peptide mapping [J].
Egelhofer, V ;
Büssow, K ;
Luebbert, C ;
Lehrach, H ;
Nordhoff, E .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2741-2750
[6]  
Guilhaus M, 2000, MASS SPECTROM REV, V19, P65, DOI 10.1002/(SICI)1098-2787(2000)19:2<65::AID-MAS1>3.0.CO
[7]  
2-E
[8]   Quantitative analysis of complex protein mixtures using isotope-coded affinity tags [J].
Gygi, SP ;
Rist, B ;
Gerber, SA ;
Turecek, F ;
Gelb, MH ;
Aebersold, R .
NATURE BIOTECHNOLOGY, 1999, 17 (10) :994-999
[9]   Design and performance of an electrospray ionization time-of-flight mass spectrometer [J].
Håkansson, K ;
Zubarev, RA ;
Håkansson, P ;
Laiko, V ;
Dodonov, AF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01) :36-41
[10]  
Hastie T., 1990, Generalized additive model