An Anatomical and Biomechanical Comparison of Anteromedial and Anterolateral Approaches for Tibial Tunnel of Posterior Cruciate Ligament Reconstruction Evaluation of the Widening Effect of the Anterolateral Approach

被引:25
作者
Ahn, Jin Hwan [2 ]
Bae, Ji Hoon [3 ]
Lee, Yong Seuk [1 ]
Choi, Kuiwon [4 ]
Bae, Tae Soo [5 ]
Wang, Joon Ho [1 ]
机构
[1] Korea Univ, Dept Orthopaed Surg, Ansan Hosp, Sch Med, Ansan 425707, Gyeongki Do, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Orthopaed Surg, Seoul, South Korea
[3] Korea Univ, Dept Orthopaed Surg, Sch Med, Guro Hosp, Seoul, South Korea
[4] Korea Inst Sci & Technol, Biomed Res Ctr, Seoul, South Korea
[5] Korea Orthopaed & Rehabil Engn Ctr, Inchon, South Korea
关键词
posterior cruciate ligament reconstruction; anterolateral approach; killer turn; transtibial tunnel technique; ARTHROSCOPIC SINGLE-BUNDLE; 2-YEAR FOLLOW-UP; TENDON AUTOGRAFT; INLAY; DEFICIENCY; ALLOGRAFT; INJURY;
D O I
10.1177/0363546509332508
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: An anterolateral approach to the tibial tunnel of posterior cruciate ligament reconstruction is used to reduce the sharpness of the graft-tunnel angle, the so-called killer turn effect. However, with the anterolateral approach, the tunnel might be widened into an ovoid shape because of the small angle between the tunnel and the anterolateral cortex. Hypothesis: The fixation strength of the posterior cruciate ligament graft in the tibial tunnel will be weaker in the anterolateral approach compared with the anteromedial approach. Study Design: Controlled laboratory study. Methods: Twenty paired cadaveric tibias were used. Tibial tunnels were made using following approaches: an anteromedial approach for 10 tibias and an anterolateral approach for 10 tibias. The anterior cortex-tunnel angle and the diameter of the tunnel entrance were measured by 2-dimensional computed tomographic scans. After fixation of the Achilles tendon allograft with a biodegradable screw, the maximal strength of the graft at failure was measured using a materials testing machine. Results: The mean cortex-tunnel angle was 47.5 degrees +/- 9.3 degrees in the anteromedial approach group and 28.3 degrees +/- 7.4 degrees in the anterolateral approach group. The mean long diameter of the tunnels in the anteromedial approach group was 10.6 +/- 1.0 mm and in the anterolateral approach group it was 14.0 +/- 1.5 mm. These two parameters showed statistically significant differences between the 2 groups (P < .01). The mean maximum load at failure for the anteromedial approach group was 385.4 +/- 139.7 N, and for the anterolateral approach group it was 225.1 +/- 144.1 N. This difference was statistically significant (P = .021). Conclusion: The anterolateral approach resulted in a tunnel with a wider entrance, a more acute cortex-tunnel angle, and a lower maximal load at failure compared with tunnels created using the anteromedial approach. Clinical Relevance: The use of additional fixation methods, such as post ties or ligament washers and screws, should be considered when using an anterolateral approach for tibial tunnel of posterior cruciate ligament reconstruction.
引用
收藏
页码:1777 / 1783
页数:7
相关论文
共 22 条
[1]
Arthroscopic transtibial posterior cruciate ligament reconstruction with preservation of posterior Cruciate ligament fibers - Clinical results of minimum 2-year follow-up [J].
Ahn, JH ;
Yang, HS ;
Jeong, TK ;
Koh, KH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (02) :194-204
[2]
Posterior cruciate ligament reconstruction: Double-loop hamstring tendon autograft versus achilles tendon allograft - Clinical results of a minimum 2-year follow-up [J].
Ahn, JH ;
Yoo, JC ;
Wang, JH .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (08) :965-969
[3]
Arthroscopic posterior cruciate ligament reconstruction using the posterior trans-septal portal [J].
Ahn, JH ;
Chung, YS ;
Oh, I .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (01) :101-107
[4]
A biomechanical comparison of posterior cruciate ligament reconstructions using single- and double-bundle tibial inlay techniques [J].
Bergfeld, JA ;
Graham, SM ;
Parker, RD ;
Valdevit, ADC ;
Kambic, HE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (07) :976-981
[5]
Evaluation of in situ graft forces of a 2-bundle tibial inlay posterior cruciate ligament reconstruction at various flexion angles [J].
Carson, Eric W. ;
Deng, Xiang Hua ;
Allen, Answorth ;
Wickiewicz, Thomas ;
Warren, Russell F. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (05) :488-495
[6]
Arthroscopic posterior cruciate ligament reconstruction with quadriceps tendon autograft - Minimal 3 years follow-up [J].
Chen, CH ;
Chen, WJ ;
Shih, CH ;
Chou, SW .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (02) :361-368
[7]
Cohen Steven B, 2004, J Knee Surg, V17, P211
[8]
Biomechanical analysis of a posterior cruciate ligament reconstruction -: Deficiency of the posterolateral structures as a cause of graft failure [J].
Harner, CD ;
Vogrin, TM ;
Höher, J ;
Ma, CB ;
Woo, SLY .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) :32-39
[9]
Reducing the "killer turn" in posterior cruciate ligament reconstruction [J].
Huang, TW ;
Wang, CJ ;
Weng, LH ;
Chan, YS .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) :712-716
[10]
ARTHROSCOPIC ASSISTED PCL RECONSTRUCTION - A TECHNICAL NOTE ON POTENTIAL NEUROVASCULAR INJURY RELATED TO DRILL BIT CONFIGURATION [J].
JACKSON, DW ;
PROCTOR, CS ;
SIMON, TM .
ARTHROSCOPY, 1993, 9 (02) :224-227