Morphologic study of three collagen materials for body wall repair

被引:63
作者
Soiderer, EE
Lantz, GC [1 ]
Kazacos, EA
Hodde, JP
Wiegand, RE
机构
[1] Purdue Univ, Dept Vet Clin Sci, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Vet Pathobiol, W Lafayette, IN 47907 USA
[3] Cook Biotech Inc, W Lafayette, IN USA
[4] Purdue Univ, Dept Stat, W Lafayette, IN 47907 USA
关键词
extracellular matrix; polypropylene mesh; small intestinal submucosa; body wall; collagen;
D O I
10.1016/S0022-4804(03)00352-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The search for ideal prostheses for body wall repair continues. Synthetic materials such as polypropylene mesh (PPM) are associated with healing complications. A porcine-derived collagen-based material (CBM), small intestinal submucosa (SIS), has been studied for body wall repair. Renal capsule matrix (RCM) and urinary bladder submucosa (UBS) are CBMs not previously evaluated in this application. This is the first implant study using RCM. Materials and methods. Full-thickness muscle/fascia ventral abdominal wall defects were repaired with SIS, RCM, UBS, and PPM in rats with omentum and omentectomy. A random complete block design was used to allot implant type to each of 96 rats. Healing was evaluated at 4 and 8 weeks. Adhesion tenacity and surface area were scored. Implant site dimensions were measured at implantation and necropsy. Inflammation, vascularization, and fibrosis were histopathologically scored. Data were compared by analysis of variance (P < 0.05). Results. PPM produced a granulomatous foreign body response in contrast to the organized healing of CBM implants. CBM mean scores were lower than PPM scores for adhesion tenacity, surface area, and inflammation at each follow-up time for rats with omentums (P < 0.02). The CBMs had less tenacity and inflammation than PPM at each follow-up time in omentectomy groups (P < 0.008). Wound contraction was greater for PPM (P < 0.0001) for all rats. Conclusions. RCM and UBS were similar to SIS invoking reduced inflammation, adhesion, and contraction compared to PPM. The fibrotic response to PPM was unique and more intense compared to CBMs. These CBM implants appear morphologically acceptable and warrant continued investigation. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:161 / 175
页数:15
相关论文
共 44 条
[1]  
[Anonymous], 2001, ABDOMINAL WALL HERNI
[2]   Morphologic study of small intestinal submucosa as a body wall repair device [J].
Badylak, S ;
Kokini, K ;
Tullius, B ;
Simmons-Byrd, A ;
Morff, R .
JOURNAL OF SURGICAL RESEARCH, 2002, 103 (02) :190-202
[3]   Strength over time of a resorbable bioscaffold for body wall repair in a dog model [J].
Badylak, S ;
Kokini, M ;
Tullius, B ;
Whitson, B .
JOURNAL OF SURGICAL RESEARCH, 2001, 99 (02) :282-287
[4]   Resorbable bioscaffold for esophageal repair in a dog model [J].
Badylak, S ;
Meurling, S ;
Chen, M ;
Spievack, A ;
Simmons-Byrd, A .
JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (07) :1097-1103
[5]   THE USE OF XENOGENEIC SMALL-INTESTINAL SUBMUCOSA AS A BIOMATERIAL FOR ACHILLES-TENDON REPAIR IN A DOG-MODEL [J].
BADYLAK, SF ;
TULLIUS, R ;
KOKINI, K ;
SHELBOURNE, KD ;
KLOOTWYK, T ;
VOYTIK, SL ;
KRAINE, MR ;
SIMMONS, C .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (08) :977-985
[6]  
BADYLAK SF, 1993, TISSUE ENGINEERING, P179
[7]   SMALL INTESTINAL SUBMUCOSA AS A LARGE DIAMETER VASCULAR GRAFT IN THE DOG [J].
BADYLAK, SF ;
LANTZ, GC ;
COFFEY, A ;
GEDDES, LA .
JOURNAL OF SURGICAL RESEARCH, 1989, 47 (01) :74-80
[8]   REPAIR OF LARGE ABDOMINAL-WALL DEFECTS WITH EXPANDED POLYTETRAFLUOROETHYLENE (PTFE) [J].
BAUER, JJ ;
SALKY, BA ;
GELERNT, IM ;
KREEL, I .
ANNALS OF SURGERY, 1987, 206 (06) :765-769
[9]  
BLEICHRODT RP, 1993, SURG GYNECOL OBSTET, V176, P18
[10]  