Maturation of the sensed electrogram amplitude over time in a new subcutaneous implantable loop recorder

被引:22
作者
Krahn, AD [1 ]
Klein, GJ [1 ]
Yee, R [1 ]
Norris, C [1 ]
机构
[1] UNIV WESTERN ONTARIO,UNIV HOSP,DEPT MED,LONDON,ON,CANADA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1997年 / 20卷 / 06期
关键词
syncope; ambulatory monitoring; loop recorder; sensing;
D O I
10.1111/j.1540-8159.1997.tb03540.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The cause of recurrent syncope may be difficult to determine if the diagnosis is not established from initial noninvasive and invasive testing. Eighteen patients with recurrent syncope and negative tilt table and electrophysiological testing underwent implantation of a left pectoral subcutaneous loop recorder. This device ''freezes'' the preceding 7.5 or 15 minute rhythm strip after magnet application after spontaneous syncope. Baseline and follow-up electrograms were routinely recorded, and patients were followed until syncope recurred. Three patients had syncope within 1 month of implantation and were excluded from this report. Implantation electrogram amplitude was 250 +/- 124 mu V and increased to 291 +/- 114 mu V at 2-3 months, and increased further to 353 +/- 167 mu V at 4-6 months (P < 0.001, ANOVA). Syncope recurred in 14 of the 15 patients. An arrhythmic basis for syncope was established (n = 7) or excluded (n = 7) in every patient who had recurrent syncope. All syncopal episodes were associated with diagnostic sensed electrograms. The increase in sensed electrogram amplitude over time suggests a maturation of the device-tissue interface. These results support the long-term viability of this implantable monitoring technique.
引用
收藏
页码:1686 / 1690
页数:5
相关论文
共 10 条
[1]  
BROWN AP, 1987, BRIT HEART J, V58, P251
[2]  
FURMAN S, 1977, J THORAC CARDIOV SUR, V73, P258
[3]   DIAGNOSIS AND NATURAL-HISTORY OF SYNCOPE AND THE ROLE OF INVASIVE ELECTROPHYSIOLOGIC TESTING [J].
KAPOOR, WN ;
HAMMILL, SC ;
GERSH, BJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (11) :730-734
[4]   A PROSPECTIVE EVALUATION AND FOLLOW-UP OF PATIENTS WITH SYNCOPE [J].
KAPOOR, WN ;
KARPF, M ;
WIEAND, S ;
PETERSON, JR ;
LEVEY, GS .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (04) :197-204
[5]   ACTIVE FIXATION ATRIAL LEADS - RANDOMIZED COMPARISON OF 2 LEAD DESIGNS [J].
KAY, GN ;
ANDERSON, K ;
EPSTEIN, AE ;
PLUMB, VJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (08) :1355-1361
[6]   THE ETIOLOGY OF SYNCOPE IN PATIENTS WITH NEGATIVE TILT-TABLE AND ELECTROPHYSIOLOGICAL TESTING [J].
KRAHN, AD ;
KLEIN, GJ ;
NORRIS, C ;
YEE, R .
CIRCULATION, 1995, 92 (07) :1819-1824
[7]   INCREMENTAL DIAGNOSTIC YIELD OF LOOP ELECTROCARDIOGRAPHIC RECORDERS IN UNEXPLAINED SYNCOPE [J].
LINZER, M ;
PRITCHETT, ELC ;
PONTINEN, M ;
MCCARTHY, E ;
DIVINE, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :214-219
[8]   LONG-TERM FOLLOW-UP OF PATIENTS WITH RECURRENT UNEXPLAINED SYNCOPE EVALUATED BY ELECTROPHYSIOLOGIC TESTING [J].
MORADY, F ;
SHEN, E ;
SCHWARTZ, A ;
HESS, D ;
BHANDARI, A ;
SUNG, RJ ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (06) :1053-1059
[9]   FEASIBILITY OF LONG-TERM ELECTROCARDIOGRAPHIC MONITORING WITH AN IMPLANTED DEVICE FOR SYNCOPE DIAGNOSIS [J].
MURDOCK, CJ ;
KLEIN, GJ ;
YEE, R ;
LEITCH, JW ;
TEO, WS ;
NORRIS, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (11) :1374-1378
[10]   UNEXPLAINED SYNCOPE EVALUATED BY ELECTROPHYSIOLOGIC STUDIES AND HEAD-UP TILT TESTING [J].
SRA, JS ;
ANDERSON, AJ ;
SHEIKH, SH ;
AVITALL, B ;
TCHOU, PJ ;
TROUP, PJ ;
GILBERT, CJ ;
AKHTAR, M ;
JAZAYERI, MR .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (12) :1013-1019