Robotic-assisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique

被引:19
作者
Browbank, I [1 ]
Bouazza-Marouf, K [1 ]
Schnabler, J [1 ]
机构
[1] Loughborough Univ Technol, Dept Mech Engn, Loughborough LE11 3TU, Leics, England
关键词
robotic-assisted orthopaedic surgery; intraoperative registration; digital X-ray photogrammetry;
D O I
10.1243/0954411001535336
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The internal fixation of proximal femoral (hip) fractures is the most frequently performed orthopaedic surgery procedure. When using a sliding compression hip screw, a commonly used fixation device, accurate positioning of the device within the femoral neck-head is achieved by initially drilling a pilot hole. A cannulated component of the hip screw is then inserted over the guide wire (surgical drill bit), which is used to drill the pilot hole. However, in practice, this fluoroscopically controlled drilling process is severely complicated by a depth perception problem and, as such, a surgeon can require several attempts to achieve a satisfactory guide wire placement. A prototype robotic-assisted orthopaedic surgery system has therefore been developed, with a view to achieving accurate right-first-time guide wire insertions. This paper describes the non-invasive digital X-ray photogrammetry-based registration technique which supports the proposed robotic-assisted drilling scenario. Results from preliminary laboratory (in vitro) trials employing this registration technique indicate that the cumulative error associated with the entire X-ray guided robotic system is within acceptable limits for the guide wire insertion process.
引用
收藏
页码:165 / 179
页数:15
相关论文
共 34 条
[1]
ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[2]
DESIGN OF FIDUCIALS FOR ACCURATE REGISTRATION USING MACHINE VISION [J].
BOSE, CB ;
AMIR, I .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (12) :1196-1200
[3]
Bouazza-Marouf K, 1995, Proc Inst Mech Eng H, V209, P51, DOI 10.1243/PIME_PROC_1995_209_316_02
[4]
Robot-assisted invasive orthopaedic surgery [J].
BouazzaMarouf, K ;
Browbank, I ;
Hewit, JR .
MECHATRONICS, 1996, 6 (04) :381-397
[5]
A DISTORTION-CORRECTION SCHEME FOR INDUSTRIAL MACHINE-VISION APPLICATIONS [J].
BUTLER, DA ;
PIERSON, PK .
IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1991, 7 (04) :546-551
[6]
Casperson L W, 1976, Med Phys, V3, P103, DOI 10.1118/1.594275
[7]
IMAGE INTENSIFIER DISTORTION CORRECTION [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1987, 14 (02) :249-252
[8]
INTERTROCHANTERIC FEMORAL FRACTURES - MECHANICAL FAILURE AFTER INTERNAL-FIXATION [J].
DAVIS, TRC ;
SHER, JL ;
HORSMAN, A ;
SIMPSON, M ;
PORTER, BB ;
CHECKETTS, RG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :26-31
[9]
DUFFIN WJ, 1980, ELECT MAGNETISM
[10]
FINLAY PA, 1995, P 2 ANN INT S MED RO, P203