In vivo study of Polyurethane-Coated Gianturco-Rosch biliary Z-stents

被引:14
作者
Severini, A [1 ]
Mantero, S [1 ]
Tanzi, MC [1 ]
Cigada, A [1 ]
Addis, F [1 ]
Cozzi, G [1 ]
Salvetti, M [1 ]
Andreola, S [1 ]
Motta, A [1 ]
Regalia, E [1 ]
Pulvirenti, A [1 ]
De Pedri, E [1 ]
Doci, R [1 ]
机构
[1] Ist Nazl Tumori, Div Radiol Gastroenterol, I-20133 Milan, Italy
关键词
bile drainage; biliary prostheses; metatlic stents;
D O I
10.1007/s002709900441
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Purpose: Prototypes of Gianturco-Rosch Z-stents coated with polycarbonate urethane (PCU) were placed in the biliary tree of pigs, in order to test their biomechanical behavior, stability, and biocompatibility. Methods: The stents were surgically implanted in the common bile duct of three pairs of pigs, which were killed after 1, 3, and 6 months respectively. Explanted livers from pigs of the same race, age, and size were used to provide comparative data. The bile ducts were radiologically and histopathologically examined; the stents were processed and examined by scanning electron microscopy. Results: No complications occurred and the animals showed a normal weight gain. The main bile duct appeared radiologically and macroscopically dilated, but the stents proved to be in place. Histologically, the bile duct epithelium was destroyed, but neither hyperplastic nor inflammatory fibrotic reactions of the wall were evident. Both the metallic structure and the polymeric coating of the stents were intact, A layer of organic material with a maximum thickness of approximately 3 mu m was evident on the inner surface of the stents. Conclusion: The present in vivo study demonstrates the biocompatibility, efficacy, and stability of PCU-coated Gianturco-Rosch stents in the biliary environment.
引用
收藏
页码:510 / 514
页数:5
相关论文
共 22 条
[1]
EVALUATION OF POLYMER-COATED BALLOON-EXPANDABLE STENTS IN BILE-DUCTS [J].
ALVARADO, R ;
PALMAZ, JC ;
GARCIA, OJ ;
TIO, FO ;
REES, CR .
RADIOLOGY, 1989, 170 (03) :975-978
[2]
MALIGNANT BILIARY OBSTRUCTION - CLINICAL AND HISTOPATHOLOGIC CORRELATION AFTER TREATMENT WITH SELF-EXPANDING METAL PROSTHESES [J].
BOGUTH, L ;
TATALOVIC, S ;
ANTONUCCI, F ;
HEER, M ;
SULSER, H ;
ZOLLIKOFER, CL .
RADIOLOGY, 1994, 192 (03) :669-674
[3]
EXPANDABLE BILIARY ENDOPROSTHESIS - AN EXPERIMENTAL-STUDY [J].
CARRASCO, CH ;
WALLACE, S ;
CHARNSANGAVEJ, C ;
RICHLI, W ;
WRIGHT, KC ;
FANNING, T ;
GIANTURCO, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (06) :1279-1281
[4]
DELVECCHIO S, 1990, GASTROENTEROL INT, V3, P92
[5]
Treatment of TIPS stenosis with ePTFE graft-covered stents [J].
DiSalle, RS ;
Dolmatch, BL .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) :172-175
[6]
CHARACTERIZATION OF THE CONTENT OF OCCLUDED BILIARY ENDOPROSTHESES [J].
GROEN, AK ;
OUT, T ;
HUIBREGTSE, K ;
DELZENNE, B ;
HOEK, FJ ;
TYTGAT, GNJ .
ENDOSCOPY, 1987, 19 (02) :57-59
[7]
Treatment of malignant biliary obstruction with polyurethane-covered wallstents [J].
Hausegger, KA ;
Thurnher, S ;
Bodendörfer, G ;
Zollikofer, CL ;
Uggowitzer, M ;
Kugler, C ;
Lammer, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :403-408
[8]
MALIGNANT BILIARY OBSTRUCTION - HISTOLOGIC-FINDINGS AFTER TREATMENT WITH SELF-EXPANDABLE STENTS [J].
HAUSEGGER, KA ;
KLEINERT, R ;
LAMMER, J ;
KLEIN, GE ;
FLUCKIGER, F .
RADIOLOGY, 1992, 185 (02) :461-464
[9]
GIANTURCO EXPANDABLE METALLIC BILIARY STENTS - RESULTS OF A EUROPEAN CLINICAL-TRIAL [J].
IRVING, JD ;
ADAM, A ;
DICK, R ;
DONDELINGER, RF ;
LUNDERQUIST, A ;
ROCHE, A .
RADIOLOGY, 1989, 172 (02) :321-326
[10]
INVITRO LONG-TERM PERFUSION OF DIFFERENT MATERIALS FOR BILIARY ENDOPROSTHESES [J].
LAMMER, J ;
STOFFLER, G ;
PETEK, WW ;
HOFLER, H .
INVESTIGATIVE RADIOLOGY, 1986, 21 (04) :329-331