Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion

被引:66
作者
Cattaneo, M [1 ]
Lecchi, A [1 ]
Agati, B [1 ]
Lombardi, R [1 ]
Zighetti, ML [1 ]
机构
[1] Univ Milan, Osped Maggiore, IRCCS, Dept Internal Med,Angelo Bianchi Bonomi Hemophili, Milan, Italy
关键词
platelet aggregation; shear stress; platelet secretion; bleeding time; desmopressin;
D O I
10.1016/S0049-3848(99)00102-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The template bleeding time is still the screening test for defects of platelet function, although it is an invasive and poorly reproducible technique. The PFA-100 measures platelet function at high shear. Whole blood is aspirated through a capillary to an aperture of a membrane coated with platelet agonists. The system measures the time required to obtain occlusion of the aperture by a platelet plug (closure time). We measured the closure times in the PFA-100 system and the bleeding time in seven patients with delta-storage pool deficiency, 10 patients with "primary secretion defect" (not due to abnormalities of platelet granules or the arachidonate pathway), and 40 controls. Measurements were repeated 1 and 4 hours after intravenous infusion of desmopressin in six delta-storage pool deficiency and eight primary secretion defect patients. Baseline bleeding time and closure times with the collagen/epinephrine cartridge were longer in delta-storage pool deficiency and primary secretion defect patients than in controls. In contrast, closure times with the collagen/adenosine diphosphate cartridge were normal in both delta-storage pool deficiency and primary secretion defect patients. Treatment with desmopressin increased the plasma von Willebrand Factor levels, shortened the prolonged bleeding time, shortened the closure times with the collagen/adenosine diphosphate cartridge, and normalized the closure times with the collagen/epinephrine cartridge, Therefore, the PFA-100 test may be a less invasive alternative to the bleeding time in the diagnosis and therapeutic monitoring of patients with platelet secretion defects. The collagen/epinephrine cartridge is more sensitive than the collagen/adenosine diphosphate cartridge to defects of platelet secretion. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 16 条
[1]  
CATTANEO M, 1995, J LAB CLIN MED, V125, P540
[2]   SUSTAINED CORRECTION OF THE BLEEDING-TIME IN AN AFIBRINOGENEMIC PATIENT AFTER INFUSION OF FRESH-FROZEN PLASMA [J].
CATTANEO, M ;
BETTEGA, D ;
LOMBARDI, R ;
LECCHI, A ;
MANNUCCI, PM .
BRITISH JOURNAL OF HAEMATOLOGY, 1992, 82 (02) :388-390
[3]  
Cattaneo M, 1997, THROMB HAEMOSTASIS, V77, P986
[4]   ROLE OF ADP IN PLATELET-AGGREGATION AT HIGH-SHEAR - STUDIES IN A PATIENT WITH CONGENITAL DEFECT OF PLATELET RESPONSES TO ADP [J].
CATTANEO, M ;
ZIGHETTI, ML ;
LOMBARDI, R ;
MANNUCCI, PM .
BRITISH JOURNAL OF HAEMATOLOGY, 1994, 88 (04) :826-829
[5]   SHEAR-INDUCED PLATELET-AGGREGATION IS POTENTIATED BY DESMOPRESSIN AND INHIBITED BY TICLOPIDINE [J].
CATTANEO, M ;
LOMBARDI, R ;
BETTEGA, D ;
LECCHI, A ;
MANNUCCI, PM .
ARTERIOSCLEROSIS AND THROMBOSIS, 1993, 13 (03) :393-397
[6]  
DANGELMAIER CA, 1983, MEASUREMENT PLATELET, P92
[7]   RAPID, SENSITIVE MICROASSAY FOR PLATELET 5HT [J].
DRUMMOND, AH ;
GORDON, JL .
THROMBOSIS ET DIATHESIS HAEMORRHAGICA, 1974, 31 (02) :366-367
[8]   Screening for von Willebrand disease with a new analyzer using high shear stress: A study of 60 cases [J].
Fressinaud, E ;
Veyradier, A ;
Truchaud, F ;
Martin, I ;
Boyer-Neumann, C ;
Trossaert, M ;
Meyer, D .
BLOOD, 1998, 91 (04) :1325-1331
[9]  
KUNDU SK, 1995, SEMIN THROMB HEMOST, V21, P106
[10]   Characterization of an in vitro platelet function analyzer, PFA-100(TM) [J].
Kundu, SK ;
Heilmann, EJ ;
Sio, R ;
Garcia, C ;
Ostgaard, RA .
CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 1996, 2 (04) :241-249