TTCA measurements in biomonitoring of low-level exposure to carbon disulphide

被引:11
作者
Kivistö, H [1 ]
机构
[1] Inst Occupat Hlth, Dept Ind Hyg & Toxicol, Helsinki 00370, Finland
关键词
carbon disulphide; 2-thiothiazolidine-4-carboxylic acid; TTCA; biomonitoring;
D O I
10.1007/s004200050426
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: The biomonitoring of carbon disulphide exposure is currently performed by measuring the concentration of 2-thiothiazolidine-4-carboxylic acid (TTCA) in the urine of exposed workers. Methods: In this study the effect of TTCA, which is found in some vegetables, on the biomonitoring of low-level carbon disulphide exposure was evaluated. In addition the upper reference limit (URL) of TTCA in the non-exposed Finnish population was estimated by analysing TTCA in urine samples from 116 people. The samples were collected at health centres all over Finland from people in employment and in the age group 24-64 years. The analytical measurements were made using a modern column-switching technique and the results were compared with those from the same samples using the extraction method generally in use and, until now, recommended for the determination of TTCA in urine. Results: The results obtained with the two analytical methods correlated very well with each other (r = 0.9). The liquid-liquid extraction method gave results constantly about 3.5 mu mol/l higher than the column-switching method. The results of this study also confirmed that many cruciferous vegetables (Cruciferae) contain endogenous TTCA (0.6-5.0 mg/kg), which is excreted unchanged in the urine. After a normal meal which included these vegetables, the TTCA concentration did not rise above the biomonitoring action level even if this was as low as 2 mmol/mol creatinine, but was easily above the URL of TTCA in the non-exposed population. The URL, calculated as the 95th percentile, was 0.3 mmol/mol creatinine. Conclusion: The results showed that the extraction method was not sufficiently specific or sensitive when the TTCA concentrations were lower than 10 mu mol/l. In contrast, the column-switching method seemed to give reliable results even at these low levels, which are the levels of interest in current practice.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 27 条
[1]  
*ACGIH, 1999, TLVS BEIS THRESH LIM
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   EVALUATION OF OCCUPATIONAL EXPOSURE TO CARBON-DISULFIDE BY BLOOD, EXHALED AIR, AND URINE ANALYSIS [J].
CAMPBELL, L ;
JONES, AH ;
WILSON, HK .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1985, 8 (02) :143-153
[4]  
Cox C, 1998, AM J IND MED, V33, P48, DOI 10.1002/(SICI)1097-0274(199801)33:1<48::AID-AJIM6>3.0.CO
[5]  
2-S
[6]  
*DFG, 1997, MAK BAT WERT LIST 19
[7]   CARBON-DISULFIDE .2. INVESTIGATIONS ON THE UPTAKE OF CS2 AND THE EXCRETION OF ITS METABOLITE 2-THIOTHIAZOLIDINE-4-CARBOXYLIC ACID AFTER OCCUPATIONAL EXPOSURE [J].
DREXLER, H ;
GOEN, T ;
ANGERER, J .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1995, 67 (01) :5-10
[8]  
EGELAND GM, 1992, BRIT J IND MED, V49, P287
[9]  
*HSE, 1997, GUID LAB TECHN OCC M
[10]  
KITAMURA S, 1993, ARCH OCCUP ENV HLTH, V65, P177