A new luminol chemiluminescence reaction using a tetravalent nickel-periodate complex as the oxidant

被引:33
作者
Yang, Chunyan [1 ]
Zhang, Zhujun [1 ]
Wang, Jinli [1 ]
机构
[1] Shaanxi Normal Univ, Coll Chem & Mat Sci, Xian 710062, Peoples R China
关键词
Chemiluminescence; Luminol; Diperiodatonickelate; Isoniazid; FLOW-INJECTION CHEMILUMINESCENCE; HYDROGEN-PEROXIDE;
D O I
10.1007/s00604-009-0223-6
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
We report on a new chemiluminescence (CL) reaction that occurs between luminol and di-periodatonickelate in alkaline medium. The possible mechanism of this system is discussed based on the kinetics of the reaction, its CL and UV spectra. The system exhibits a sensitivity that is higher than any other system based on luminol. It was successfully applied to the determination of isoniazid in serum.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 19 条
[1]
Effect of eluent composition and pH and chemiluminescent reagent pH on ion chromatographic selectivity and luminol-based chemiluminescence detection of Co2+, Mn2+ and Fe2+ at trace levels [J].
Badocco, Denis ;
Pastore, Paolo ;
Favaro, Gabriella ;
Macca, Carlo .
TALANTA, 2007, 72 (01) :249-255
[2]
Coupling microdialysis with flow-injection chemiluminescence detection for a protein-drug interaction study [J].
Chen, Hua ;
Gong, Zhengjun ;
Zhang, Zhujun .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) :1412-1417
[3]
Ultrasensitive flow injection chemiluminescence detection of DNA hybridization using nanoCuS tags [J].
Ding, Caifeng ;
Zhong, Hua ;
Zhang, Shusheng .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (08) :1314-1318
[4]
Ultrasound-enhanced flow injection chemiluminescence for determination of hydrogen peroxide [J].
Greenway, GM ;
Leelasattarathkul, T ;
Liawruangrath, S ;
Wheatley, RA ;
Youngvises, N .
ANALYST, 2006, 131 (04) :501-508
[5]
A flow injection chemiluminescence system for the determination of isoniazid [J].
Huang, YM ;
Zhang, ZJ ;
Zhang, DJ ;
Lv, J .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04) :429-431
[6]
Chemiluminescence detection of isoniazid using Ru(phen)32+-isoniazid-Ce(IV) system [J].
Juan, X ;
Shi, B ;
Ai, XP ;
He, ZK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (01) :237-241
[7]
Flow injection chemiluminescence determination of isoniazid using on-line electrogenerated manganese(III) as oxidant [J].
Li, BX ;
Zhang, ZJ ;
Zheng, XW ;
Xu, CL .
MICROCHEMICAL JOURNAL, 1999, 63 (03) :374-380
[8]
Highly sensitive electrogenerated chemiluminescence isoniazid with NiO nanoparticles-modified graphite electrode [J].
Li, Guixin ;
Zheng, Xingwang .
ANALYTICAL LETTERS, 2007, 40 (10) :1853-1863
[9]
Graft copolymerization of butyl acrylate onto casein initiated by potassium diperiodatonickelate(IV) in alkaline medium [J].
Liu, YH ;
Zhang, YZ ;
Liu, ZH ;
Deng, KL .
EUROPEAN POLYMER JOURNAL, 2002, 38 (08) :1619-1625
[10]
Reactive oxygen species and their chemiluminescence-detection methods [J].
Lu, Chao ;
Song, Guanqun ;
Lin, Jin-Ming .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (10) :985-995