Wireless Instantaneous Neurotransmitter Concentration System-based amperometric detection of dopamine, adenosine, and glutamate for intraoperative neurochemical monitoring Laboratory investigation

被引:53
作者
Agnesi, Filippo [2 ]
Tye, Susannah J. [1 ]
Bledsoe, Jonathan M. [1 ]
Griessenauer, Christoph J. [1 ]
Kimble, Christopher J. [3 ]
Sieck, Gary C. [2 ]
Bennet, Kevin E. [3 ]
Garris, Paul A. [4 ]
Blaha, Charles D. [5 ]
Lee, Kendall H. [1 ,2 ]
机构
[1] Mayo Clin, Dept Neurol Surg, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[3] Mayo Clin, Div Engn, Rochester, MN 55905 USA
[4] Illinois State Univ, Dept Biol Sci, Normal, IL 61761 USA
[5] Univ Memphis, Dept Psychol, Memphis, TN 38152 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
deep brain stimulation; motor cortex stimulation; pig; amperometry; dopamine; glutamate; adenosine; rat; DEEP BRAIN-STIMULATION; CENTRAL-NERVOUS-SYSTEM; CARBON-FIBER MICROELECTRODES; HIGH-FREQUENCY STIMULATION; NUCLEUS-TRACTUS-SOLITARII; IN-VIVO; SUBTHALAMIC NUCLEUS; MULTISITE MICROELECTRODE; EXTRACELLULAR GLUCOSE; ESSENTIAL TREMOR;
D O I
10.3171/2009.3.JNS0990
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In a companion study, the authors describe the development of a new instrument named the Wireless Instantaneous Neurotransmitter Concentration System (WINCS), which couples digital telemetry with fast-scan cyclic voltammetry (FSCV) to measure extracellular concentrations of dopamine. In the present study, the authors describe the extended capability of the WINCS to use fixed potential amperometry (FPA) to measure extracellular concentrations of dopamine, as well as glutamate and adenosine. Compared with other electrochemical techniques such as FSCV or high-speed chronoamperometry, FPA offers superior temporal resolution and, in combination with enzyme-linked biosensors, the potential to monitor nonelectroactive analytes in real time. Methods. The WINCS design incorporated a transimpedance amplifier with associated analog circuitry for FPA; a microprocessor; a Bluetooth transceiver; and a single, battery-powered, multilayer, printed circuit board. The WINCS was tested with 3 distinct recording electrodes: 1) a carbon-fiber microelectrode (CFM) to measure dopamine; 2) a glutamate oxidase enzyme-linked electrode to measure glutamate; and 3) a multiple enzyme-linked electrode (adenosine deaminase, nucleoside phosphorylase, and xanthine oxidase) to measure adenosine. Proof-of-principle analyses included noise assessments and in vitro and in vivo measurements that were compared with similar analyses by using a commercial hardwired electrochemical system (EA161 Picostat, eDAQ; Pty Ltd). In urethane-anesthetized rats, dopamine release was monitored in the striatum following deep brain stimulation (DBS) of ascending dopaminergic fibers in the medial forebrain bundle (MFB). In separate rat experiments, DBS-evoked adenosine release was monitored in the ventrolateral thalamus. To test the WINCS in an operating room setting resembling human neurosurgery, cortical glutamate release in response to motor cortex stimulation (MCS) was monitored using a large-mammal animal model, the pig. Results. The WINCS, which is designed in compliance with FDA-recognized consensus standards for medical electrical device safety, successfully measured dopamine, glutamate, and adenosine, both in vitro and in vivo. The WINCS detected striatal dopamine release at the implanted CFM during DBS of the MFB. The DBS-evoked adenosine release in the rat thalamus and MCS-evoked glutamate release in the pig cortex were also successfully measured. Overall, in vitro and in vivo testing demonstrated signals comparable to a commercial hardwired electrochemical system for FPA. Conclusions. By incorporating FPA, the chemical repertoire of WINCS-measurable neurotransmitters is expanded to include glutamate and other nonelectroactive species for which the evolving field of enzyme-linked biosensors exists. Because many neurotransmitters are not electrochemically active, FPA in combination with enzyme-linked microelectrodes represents a powerful intraoperative tool for rapid and selective neurochemical sampling in important anatomical targets during functional neurosurgery. (DOI: 10.3171/2009.3.JNS0990)
引用
收藏
页码:701 / 711
页数:11
相关论文
共 45 条
[1]  
AILLON D, 2008, P 12 INT C IN VIV ME
[2]   Mechanisms of deep brain stimulation: an intracellular study in rat thalamus [J].
Anderson, T ;
Hu, B ;
Pittman, Q ;
Kiss, ZHT .
JOURNAL OF PHYSIOLOGY-LONDON, 2004, 559 (01) :301-313
[3]   Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes [J].
Bath, BD ;
Michael, DJ ;
Trafton, BJ ;
Joseph, JD ;
Runnels, PL ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 2000, 72 (24) :5994-6002
[4]   Adenosine is crucial for deep brain stimulation-mediated attenuation of tremor [J].
Bekar, Lane ;
Libionka, Witold ;
Tian, Guo-Feng ;
Xu, Qiwu ;
Torres, Arnulfo ;
Wang, Xiaohai ;
Lovatt, Ditte ;
Williams, Erika ;
Takano, Takahiro ;
Schnermann, Jurgen ;
Bakos, Robert ;
Nedergaard, Maiken .
NATURE MEDICINE, 2008, 14 (01) :75-80
[5]   BRAIN MICRODIALYSIS [J].
BENVENISTE, H .
JOURNAL OF NEUROCHEMISTRY, 1989, 52 (06) :1667-1679
[6]  
Blaha CD, 1996, BEHAV PHARMACOL, V7, P675
[7]  
BLEDSOE JM, 2008, NEUROSCIENCE 2008 M
[8]   Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry Technical note [J].
Bledsoe, Jonathan M. ;
Kimble, Christopher J. ;
Covey, Daniel P. ;
Blaha, Charles D. ;
Agnesi, Filippo ;
Mohseni, Pedram ;
Whitlock, Sidney ;
Johnson, David M. ;
Horne, April ;
Bennet, Kevin E. ;
Lee, Kendall H. ;
Garris, Paul A. .
JOURNAL OF NEUROSURGERY, 2009, 111 (04) :712-723
[9]   Neurochemical mechanisms induced by high frequency stimulation of the subthalamic nucleus: Increase of extracellular striatal glutamate and GABA in normal and hemiparkinsonian rats [J].
Bruet, N ;
Windels, F ;
Carcenac, C ;
Feuerstein, C ;
Bertrand, A ;
Poupard, A ;
Savasta, M .
JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2003, 62 (12) :1228-1240
[10]   Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS [J].
Burmeister, JJ ;
Pomerleau, F ;
Palmer, M ;
Day, BK ;
Huettl, P ;
Gerhardt, GA .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 119 (02) :163-171