Comparison of Periprosthetic Tissue Digestion Methods for Ultra-High Molecular Weight Polyethylene Wear Debris Extraction

被引:22
作者
Baxter, Ryan M. [1 ]
Steinbeck, Maria J. [1 ]
Tipper, Joanne L. [2 ]
Parvizi, Javad [3 ]
Marcolongo, Michele [4 ]
Kurtz, Steve M. [1 ,5 ]
机构
[1] Drexel Univ, Dept Biomed Engn, Philadelphia, PA 19104 USA
[2] Univ Leeds, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
[3] Thomas Jefferson Univ, Rothman Inst Orthoped, Philadelphia, PA 19107 USA
[4] Drexel Univ, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
[5] Exponent Inc, Philadelphia, PA 19104 USA
关键词
ultra-high molecular weight polyethylene; wear debris; periprosthetic tissue; tissue digestion; TOTAL JOINT ARTHROPLASTIES; TOTAL KNEE REPLACEMENTS; TOTAL HIP REPLACEMENTS; IN-VITRO; INFLAMMATORY RESPONSE; INDUCED OSTEOLYSIS; UHMWPE PARTICLES; SIZE; BONE; VIVO;
D O I
10.1002/jbm.b.31416
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
There is considerable interest in characterization of wear debris from polyethylene (UHMWPE) bearing components used in total joint replacement. To isolate UHMWPE wear debris, tissue samples must be excised from regions adjacent to revised UHMWPE implant components, followed by exposure to one of many available tissue digestion methods. Numerous studies demonstrate successful digestion, but the relative efficiency of each method is not clear. The purpose of this study was to evaluate a variety of conditions for tissue digestion to provide a quantitative comparison of methods. Porcine and human hip tissues were exposed for 24 h to basic, acidic or enzymatic agents, filtered and digestion efficiency calculated based on the percentage of initial to final tissue weight. Of the conditions tested, 5 M NaOH, 5 M KOH,15 M KOH or 15.8 M HNO3 yielded the most complete porcine hip tissue digestion (<1 % residual tissue weight; p < 0.05). Proteinase K and Liberase Blendzyme 3 did not effectively digest tissue in a 24 h period. Similar to results from the porcine dataset, human tissues digestion was most efficient using 5 M NaOH, 5 M KOH or 15.8 M HNO3 (<1% residual tissue weight; p < 0.05). To verify that particle surface modifications did not occur after prolonged reagent exposure, GUR415 and Ceridust 3715 particles were immersed in each solution for 24 h. Overall, this study provides a framework for thorough and efficient digestive methods for UHMWPE wear debris extraction. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 91B: 409-418, 2009
引用
收藏
页码:409 / 418
页数:10
相关论文
共 49 条
[1]
Osteolysis - basic science, incidence and diagnosis [J].
Agarwal, S .
CURRENT ORTHOPAEDICS, 2004, 18 (03) :220-231
[2]
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[3]
*ASTM INT, 2005, F561 ASTM INT
[4]
TISSUE DIGESTION FOR WEAR DEBRIS PARTICLE ISOLATION [J].
CAMPBELL, P ;
MA, S ;
SCHMALZRIED, T ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (04) :523-526
[5]
ISOLATION OF PREDOMINANTLY SUBMICRON-SIZED UHMWPE WEAR PARTICLES FROM PERIPROSTHETIC TISSUES [J].
CAMPBELL, P ;
MA, S ;
YEOM, B ;
MCKELLOP, H ;
SCHMALZRIED, TP ;
AMSTUTZ, HC .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :127-131
[6]
Catelas I, 2001, J BIOMED MATER RES, V55, P330, DOI 10.1002/1097-4636(20010605)55:3<330::AID-JBM1021>3.0.CO
[7]
2-Y
[8]
Catelas I, 2001, J BIOMED MATER RES, V55, P320, DOI 10.1002/1097-4636(20010605)55:3<320::AID-JBM1020>3.0.CO
[9]
2-3
[10]
The effect of ultra-high molecular weight polyethylene wear debris on MG63 osteosarcoma cells in vitro [J].
Dean, DD ;
Schwartz, Z ;
Liu, Y ;
Blanchard, CR ;
Agrawal, CM ;
Mabrey, JD ;
Sylvia, VL ;
Lohmann, CH ;
Boyan, BD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :452-461