Functional impact of axonal misdirection after peripheral nerve injuries followed by graft or tube repair

被引:70
作者
Valero-Cabré, A
Navarro, X [1 ]
机构
[1] Univ Autonoma Barcelona, Fac Med, Neuroplast & Regenerat Grp, Dept Cell Biol Physiol & Immunol, Bellaterra 08193, Spain
[2] Harvard Univ, Sch Med, Dept Neurol, Boston, MA 02115 USA
关键词
accuracy of reinnervation; axonal regeneration; electrophysiology; misdirection; peripheral nerve; tubulization;
D O I
10.1089/089771502320914705
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Accuracy of reinnervation is one of the main factors conditioning functional recovery after brain, spinal, or peripheral axonal damage. Using the peripheral nerve as an experimental model, we studied the amount of inaccurate muscle reinnervation and its consequences on walking. Adult rats were submitted to an 8-mm resection of the sciatic nerve repaired by autograft (AG, n = 9), silicone (SIL, n = 13) or poly-L-lactate-epsilon-caprolactone (PLC, n = 11) single guides, and fascicular tubulization of peroneal and tibial branches with a dual silicone tube (FSIL, n = 9). At the end of follow-up, the sciatic nerve and its tibial and peroneal fascicles were dissected and stimulated by means of a suction electrode. In control rats, gastrocnemius and plantar muscles are fully innervated by the tibial fascicle and the tibialis anterior muscle by the peroneal nerve. None of the groups had noticeable recovery of locomotion assessed by the walking track index (SFI around -70 in all groups). After resection, all animals of groups AG, SIL, and PLC showed aberrant muscle reinnervation by axons from a non-corresponding fascicle, whereas in group FSIL only one of six regenerated animals showed misdirected activity. The proportion of inaccurate muscle activation was similar in group AG (47% for gastrocnemius, 54% for tibialis anterior, and 44% for plantar muscles) and in group SIL (42%, 42 %, and 42 %), and reduced in group PLC (26 %, 38 %, and 27 %). In conclusion, fascicular silicone tubulization allowed the highest degree of accuracy but the lowest recovery, whereas resorbable PLC guides provided for the best balance between amount and accuracy of reinnervation after nerve resection.
引用
收藏
页码:1475 / 1485
页数:11
相关论文
共 48 条
[1]  
ABERNETHY DA, 1992, J ANAT, V180, P395
[2]   An anterograde degeneration study of the distribution of regenerating rat myelinated fibers in the silicone chamber model [J].
Alzate, LH ;
Sutachan, JJ ;
Hurtado, H .
NEUROSCIENCE LETTERS, 2000, 286 (01) :17-20
[3]  
Angelov DN, 1996, J NEUROSCI, V16, P1041
[4]   RECOVERY OF ORIGINAL NERVE SUPPLY AFTER HYPOGLOSSAL FACIAL ANASTOMOSIS CAUSES PERMANENT MOTOR HYPERINNERVATION OF THE WHISKER-PAD MUSCLES IN THE RAT [J].
ANGELOV, DN ;
GUNKEL, A ;
STENNERT, E ;
NEISS, WF .
JOURNAL OF COMPARATIVE NEUROLOGY, 1993, 338 (02) :214-224
[5]  
ARCHIBALD SJ, 1995, J NEUROSCI, V15, P4109
[6]   NERVE CABLES FORMED IN SILICONE CHAMBERS RECONSTITUTE A PERINEURIAL BUT NOT A VASCULAR ENDONEURIAL PERMEABILITY BARRIER [J].
AZZAM, NA ;
ZALEWSKI, AA ;
WILLIAMS, LR ;
AZZAM, RN .
JOURNAL OF COMPARATIVE NEUROLOGY, 1991, 314 (04) :807-819
[7]   NONSELECTIVITY IN ESTABLISHMENT OF NEUROMUSCULAR CONNECTIONS FOLLOWING NERVE REGENERATION INRAT [J].
BERNSTEIN, J ;
GUTH, L .
EXPERIMENTAL NEUROLOGY, 1961, 4 (03) :262-&
[8]  
BodineFowler SC, 1997, MUSCLE NERVE, V20, P29, DOI 10.1002/(SICI)1097-4598(199701)20:1<29::AID-MUS4>3.0.CO
[9]  
2-J
[10]  
Brushart T M, 1990, Restor Neurol Neurosci, V1, P281, DOI 10.3233/RNN-1990-13416