Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM

被引:47
作者
Francescon, P [1 ]
Cavedon, C [1 ]
Reccanello, S [1 ]
Cora, S [1 ]
机构
[1] San Bortolo Hosp, Dept Med Phys, Vicenza, Italy
关键词
Monte Carlo; treatment planning; photon dose calculation;
D O I
10.1118/1.599024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to compare the photon dose calculation of a commercially available three-dimensional (3D) treatment planning system based on the collapsed cone convolution technique against BEAM, a Monte Carlo code that allows detailed simulation of a radiotherapy accelerator. The first part of the work is devoted to the commissioning of BEAM for a 6 MV photon beam and to the optimization of the linac description to fit the experimental data. This step also involves a comparison with radiochromic film data on an inhomogeneous phantom built to simulate electronic nonequilibrium conditions. Commissioning the selected photon beams required a careful description of the treatment head and the fine tuning of physical parameters such as electron beam energy and radius. The second part shows the dose comparison for real patient's CT data sets: A mediastinal treatment and a breast treatment were simulated. Doses in terms of absolute values per monitor unit were calculated based on the BEAM simulation of the CT data sets. For comparisons of real-patient cases, differences between the treatment planning system and BEAM ranged from 0 to 2.6% and were within +/-2 standard deviations for the dose calculated at the prescription point. Dose-volume histogram analysis indicated that there is no consistent difference between the Monte Carlo and the convolution calculations. On the basis of the results presented in this study, we can conclude that the CCC algorithm is capable of giving results absolutely comparable to those of a Monte Carlo calculation, as far as common 3D radiotherapy planning is concerned. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00507-1].
引用
收藏
页码:1579 / 1587
页数:9
相关论文
共 33 条
[1]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[3]  
AHNESJO A, 1992, 5 WORKSH 3 DIM TREAT
[4]  
ALTSHULER DM, 1991, DEV VISUAL SYSTEM, V3, P37
[5]  
Battista Jerry J., 1992, Australasian Physical and Engineering Sciences in Medicine, V15, P159
[6]   A COMPARISON OF AIR-CAVITY INHOMOGENEITY EFFECTS FOR CO-60, 6-MV, AND 10-MV X-RAY-BEAMS [J].
BEACH, JL ;
MENDIONDO, MS ;
MENDIONDO, OA .
MEDICAL PHYSICS, 1987, 14 (01) :140-144
[7]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[8]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[9]   CALCULATION OF PHOTON DOSE DISTRIBUTIONS IN AN INHOMOGENEOUS-MEDIUM USING CONVOLUTIONS [J].
BOYER, AL ;
MOK, EC .
MEDICAL PHYSICS, 1986, 13 (04) :503-509
[10]  
DUANE S, 1989, PIRS0173 NAT RES COU