The "genetic sonogram": Comparison of the index scoring system with the age-adjusted US risk assessment

被引:36
作者
Winter, TC
Uhrich, SB
Souter, VL
Nyberg, DA
机构
[1] Univ Washington, Dept Radiol, Div Ultrasound, Seattle, WA 98195 USA
[2] Univ Washington, Dept Obstet & Gynecol, Div Perinatal Med, Seattle, WA 98195 USA
[3] Swedish Med Ctr, Ctr Perinatal Studies, Seattle, WA USA
关键词
Down syndrome; fetus; abnormalities; US;
D O I
10.1148/radiology.215.3.r00ma36775
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare two ultrasonographic (US) methods for prenatal detection of fetal Down syndrome. MATERIALS AND METHODS: Genetic amniocentesis Was successfully performed in 3,303 consecutive women with high-risk pregnancies (mean gestational age, 17.1 weeks). All patients underwent a complete "genetic US" examination prospectively. Risk was assessed by using (a) various modifications of the index scoring system (ISS) and (b) the age-adjusted US risk assessment (AAURA). RESULTS: The prevalence of Down syndrome in this population was 1.6% (53 of 3,303). By using a threshold of at least 2 points to detect trisomy 21, the best ISS had a sensitivity of 45.3%, false-positive rate of 4.9%, likelihood ratio of 9.3, and positive predictive value in the high-risk population in this study of 13.3%. Lowering the threshold to 1 point increased the sensitivity to 60.4% but increased the false-positive rate to 15.8%. Adding points for age increased the sensitivity to 67.9% but increased the false-positive rate to 24.3%. Results of using AAURA to detect trisomy 21 were nearly identical, with a sensitivity of 43.4% and false-positive rate of 4.9% at a 1 in 36 risk threshold and a sensitivity of 69.8% and false-positive rate of 26.1% at a 1 in 200 threshold. Trisomies 18 and 13 were detected with sensitivities of 80.0% and 100.0%, respectively, with either system. CONCLUSION: The modified ISS and AAURA are equivalent in screening for Down syndrome, with detection of approximately half of all trisomy 21 fetuses at a 5% false-positive rate.
引用
收藏
页码:775 / 782
页数:8
相关论文
共 55 条
[1]   Prenatal ultrasonographic diagnosis of fetal heart echogenic foci: No correlation with down syndrome [J].
Achiron, R ;
Lipitz, S ;
Gabbay, U ;
Yagel, S .
OBSTETRICS AND GYNECOLOGY, 1997, 89 (06) :945-948
[2]   DOWNS-SYNDROME - RECENT TRENDS IN THE UNITED-STATES [J].
ADAMS, MM ;
ERICKSON, JD ;
LAYDE, PM ;
OAKLEY, GP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1981, 246 (07) :758-760
[3]  
*AM I ULTR MED, 1992, J ULTRAS MED, V11, P171
[4]   An alternative for women initially declining genetic amniocentesis: Individual Down syndrome odds on the basis of maternal age and multiple ultrasonographic markers [J].
Bahado-Singh, R ;
Deren, O ;
Oz, U ;
Tan, A ;
Hunter, D ;
Copel, J ;
Mahoney, MJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (02) :514-519
[5]   FETUSES WITH DOWN-SYNDROME HAVE DISPROPORTIONATELY SHORTENED FRONTAL-LOBE DIMENSIONS ON ULTRASONOGRAPHIC EXAMINATION [J].
BAHADOSINGH, RO ;
WYSE, L ;
DORR, MA ;
COPEL, JA ;
OCONNOR, T ;
HOBBINS, JC .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (04) :1009-1014
[6]   CAN SONOGRAPHERS RELIABLY IDENTIFY ANATOMIC FEATURES ASSOCIATED WITH DOWN SYNDROME IN FETUSES [J].
BENACERRAF, BR ;
CNANN, A ;
GELMAN, R ;
LABODA, LA ;
FRIGOLETTO, FD .
RADIOLOGY, 1989, 173 (02) :377-380
[7]   HUMERAL SHORTENING IN 2ND-TRIMESTER FETUSES WITH DOWN-SYNDROME [J].
BENACERRAF, BR ;
NEUBERG, D ;
FRIGOLETTO, FD .
OBSTETRICS AND GYNECOLOGY, 1991, 77 (02) :223-227
[8]  
BENACERRAF BR, 1990, OBSTET GYNECOL, V76, P58
[9]   Use of sonographic markers to determine the risk of down syndrome in second-trimester fetuses [J].
Benacerraf, BR .
RADIOLOGY, 1996, 201 (03) :619-620
[10]   SONOGRAPHIC DIAGNOSIS OF DOWN SYNDROME IN THE 2ND TRIMESTER [J].
BENACERRAF, BR ;
FRIGOLETTO, FD ;
LABODA, LA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 153 (01) :49-52