Predicting the microclimate inside a greenhouse: an application of a one-dimensional numerical model in an unheated greenhouse

被引:31
作者
Zhang, YS [1 ]
Mahrer, Y [1 ]
Margolin, M [1 ]
机构
[1] HEBREW UNIV JERUSALEM,FAC AGR,SEAGRAM CTR SOIL & WATER SCI,IL-76100 REHOVOT,ISRAEL
关键词
greenhouse; microclimate; leaf wetness duration; relative humidity; leaf temperature;
D O I
10.1016/S0168-1923(96)02422-7
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
A one-dimensional numerical model has been adapted to predict the microclimate inside an unheated commercial greenhouse during a continuous period of 51 days. The main outputs of the model (hourly air and leaf temperatures and relative humidity) were used to derive the leaf wetness duration (LWD) each day. Measured microclimate parameters inside the greenhouse were used to test the model performance during the corresponding period. Reasonable agreement was found between the predicted and measured parameters for the entire period. The root mean square differences between the predicted and actual air and leaf temperatures, relative humidity and LWD were 1.2 and 1.8 degrees C, 5.8% and 1.9 h d(-1), respectively. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 15 条
[1]  
AVISSAR R, 1982, T ASAE, V25, P1711
[2]  
BUSINGER JA, 1963, PHYSICS PLANT ENV, P273
[3]   ADAPTATION OF A DEW ESTIMATION SCHEME TO A NEW CROP AND SITE [J].
GILLESPIE, TJ ;
BARR, A .
AGRICULTURAL AND FOREST METEOROLOGY, 1984, 31 (3-4) :289-295
[4]  
GLEASON ML, 1994, PLANT DIS, V78, P1011, DOI 10.1094/PD-78-1011
[5]   MODELING LEAF WETNESS IN RELATION TO PLANT-DISEASE EPIDEMIOLOGY [J].
HUBER, L ;
GILLESPIE, TJ .
ANNUAL REVIEW OF PHYTOPATHOLOGY, 1992, 30 :553-577
[6]  
JAKOB M, 1949, HEAT TRANSFER, P758
[7]   SIMULATION OF ENERGY BALANCE OF A GREENHOUSE [J].
KIMBALL, BA .
AGRICULTURAL METEOROLOGY, 1973, 11 (02) :243-260
[9]  
SEARS FW, 1960, COLL PHYSICS
[10]  
TAKAKURA T, 1989, Acta Horticulturae (Wageningen), P49