Short-wavelength automated perimetry: It's role in the clinic and for understanding ganglion cell function

被引:58
作者
Sample, PA
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, Visual Funct Lab, La Jolla, CA 92093 USA
关键词
D O I
10.1016/S1350-9462(00)00001-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Short-wavelength automated perimetry (SWAP) is a more sensitive Lest than standard achromatic perimetry for early loss of vision due to glaucoma and other ocular and neurological diseases. SWAP is also more successful for detecting changes in vision as glaucoma progresses. Results from various visual function-specific tests, including SWAP, suggest that there are individual differences in ocular hypertensive and glaucoma eyes in the subtype of ganglion cell first affected. However, the disease targets the same retinal area for all function-specific tests that show a deficit in a given individual. Psychophysical tests of vision are critical to understand glaucoma's effect on retinal ganglion cells, to verify the success or failure of treatment including new neuroprotective agents, and to determine the relationship of genetic markers for glaucoma to the presence and progress of the disease. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:369 / 383
页数:15
相关论文
共 126 条
[1]  
ADAMS AJ, 1982, INVEST OPHTH VIS SCI, V23, P516
[2]  
Allingham RR, 1998, INVEST OPHTH VIS SCI, V39, P2288
[3]   Clinical features associated with mutations in the chromosome 1 open-angle glaucoma gene (GLCIA) [J].
Alward, WLM ;
Fingert, JH ;
Coote, MA ;
Johnson, AT ;
Lerner, SF ;
Junqua, D ;
Durcan, FJ ;
McCartney, PJ ;
Mackey, DA ;
Sheffield, VC ;
Stone, EM .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (15) :1022-1027
[4]   A gene responsible for the pigment dispersion syndrome maps to chromosome 7q35-q36 [J].
Andersen, JS ;
Pralea, AM ;
DelBono, EA ;
Haines, JL ;
Gorin, MB ;
Schuman, JS ;
Mattox, CG ;
Wiggs, JL .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (03) :384-388
[5]  
AUBERT H, 1857, A VONFRAEFES ARCH KL, V3, P38
[6]  
Bathija R, 1998, J GLAUCOMA, V7, P121
[7]  
Bengtsson B, 1997, ACTA OPHTHALMOL SCAN, V75, P368
[8]  
BLUMENTHAL EZ, 1999, IN PRESS AM J OPHTHA
[9]   AGE-RELATED-CHANGES IN THE HUMAN LENS - A COMPARISON OF SCHEIMPFLUG PHOTOGRAPHY AND LENS DENSITY INDEX [J].
BOSEM, ME ;
SAMPLE, PA ;
MARTINEZ, GA ;
LUSKY, M ;
WEINREB, RN .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01) :70-73
[10]   Motion automated perimetry identifies early glaucomatous field defects [J].
Bosworth, CF ;
Sample, PA ;
Gupta, N ;
Bathija, R ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (09) :1153-1158