Automated flow injection system for the preconcentration of bismuth and lead from acid solutions of alloys and determination by electrothermal atomic absorption spectrometry

被引:41
作者
Giacomelli, MBO
Ganzarolli, EM
Curtius, AJ [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Sul Santa Catarina, BR-88704900 Tubarao, SC, Brazil
关键词
electrothermal atomic absorption spectrometry; dithiophosphoric acid O; O-diethyl ester; on line preconcentration; alloys; aluminum; lead;
D O I
10.1016/S0584-8547(00)00184-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An automated flow injection system for the preconcentration of Bi and Pb from acid solutions of alloys is proposed. The system uses three-way solenoid valves, a peristaltic pump, a mixing coil and a minicolumn filled with activated carbon. The valves are time-based controlled by a microcomputer using a program written in Turbo Pascal 4.0. Bismuth(III) and Pb(II) are preconcentrated on activated carbon after complexation with the ammonium salt of dithiophosphoric acid O,O-diethyl ester. Ethanol is used as the eluent in a reverse-flow mode, and is delivered into the autosampler cup of the electrothermal atomic absorption spectrometer. Four certified steel samples and a non-certified aluminum foil, spiked with the analytes, were analyzed after microwave-assisted dissolution with acids. For the steel samples, ascorbic acid was added to the sample solution to reduce Fe(III) to Fe(II). Iron(II) and Al(III) do not react with the complexing agent and are separated in the preconcentration step. The obtained analyte concentrations were in agreement with the certified or recommended values. The recoveries for the spiked aluminum sample were between 88 and 110%. The relative standards deviations were reasonable for a non-commercial flow system, ranging from 4 to 19%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 23 条
[1]   DETERMINATION OF SILVER IN WATERS AND SOIL BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER COMPLEXATION AND SORPTION ON CARBON [J].
AVILA, AK ;
CURTIUS, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (04) :543-546
[2]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[3]   DITHIOPHOSPHORIC-ACID-O,O-DIETHYLESTER FOR TRACE ENRICHMENT ON ACTIVATED CARBON .1. ANALYSIS OF HIGH-PURITY GALLIUM AND ALUMINIUM-DETERMINATION OF THE ELEMENT TRACES BY FLAME-AAS (INJECTION METHOD AND LOOP-AAS) [J].
BERNDT, H ;
MESSERSCHMIDT, J .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 308 (02) :104-111
[4]   DITHIOPHOSPHORIC-ACID-O,O-DIETHYLESTER FOR TRACE ENRICHMENT ON ACTIVATED CARBON .2. ANALYSIS OF HIGH-PURITY IRON CHROMIUM AND MANGANESE [J].
BERNDT, H ;
MESSERSCHMIDT, J ;
REITER, E .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 310 (3-4) :230-233
[5]  
BODE H, 1962, FRESEN Z ANAL CHEM, V185, P99
[6]   A CONTRIBUTION TO THE TRACE ANALYSIS OF HIGH-PURITY IRON BY ATOMIC SPECTROMETRY (FLAME-AAS, FURNACE-AAS, ICP-OES) [J].
CHEN, JS ;
BERNDT, H ;
TOLG, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (12) :526-534
[7]  
da Silva JBB, 1998, MICROCHEM J, V60, P249
[8]  
da Silva JBB, 1999, ANALYST, V124, P1249
[9]   FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF CADMIUM IN BIOLOGICAL SAMPLES USING A PRECONCENTRATION FLOW SYSTEM WITH AN ACTIVATED CARBON COLUMN AND DITHIZONE AS A CHELATING AGENT [J].
DEPENA, YP ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (06) :691-696
[10]   Automated potentiometric titrator based in monosegmented flow system. [J].
Ganzarolli, EM ;
Lehmkuhl, A ;
de Queiróz, RRR ;
de Souza, IG .
QUIMICA NOVA, 1999, 22 (01) :53-57