共 20 条
Balloon-assist technique for endovascular coil embolization of geometrically difficult intracranial aneurysms
被引:107
作者:
Malek, AM
Halbach, VV
Phatouros, CC
Lempert, TE
Meyers, PM
Dowd, CF
Higashida, RT
机构:
[1] Univ Calif San Francisco, Dept Radiol, Div Intervent Neurovasc Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Neurosurg, San Francisco, CA 94143 USA
关键词:
balloon catheter;
carotid aneurysm;
Guglielmi detachable coil;
microcatheter techniques;
ophthalmic aneurysm;
stroke;
D O I:
10.1097/00006123-200006000-00022
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
OBJECTIVE: The balloon-assist or neck-remodeling technique is an adjunctive method devised for the endovascular coil embolization of aneurysms characterized by a wide neck or unfavorable geometric features. Since its initial description, there have been few data to corroborate its utility, efficacy, and safety in aneurysm embolization. METHODS: Twenty patients (19 female patients and 1 male patient) with 22 aneurysms (19 unruptured aneurysms and 3 ruptured aneurysms) underwent balloon-assisted coil embolization. The balloon-assist technique was performed in the same treatment session after conventional coil embolization had failed in 55% of cases (12 of 22 cases) and was the primary treatment in 45% of cases. The majority of aneurysms were located in the supraclinoid carotid artery (13 paraophthalmic and 3 superior hypophyseal aneurysms). The mean angiographic measurements included a fundus of 8.7 +/- 3.7 mm, a neck of 5.3 +/- 2.2 mm, and a comparatively unfavorable fundus/neck ratio of 1.33 +/- 0.23. RESULTS: Technical success was achieved in 77% of cases (17 of 22). The rate of aneurysm obliteration at the end of the procedures was 97 +/- 3.8%. Angiographic follow-up data (mean follow-up period, 10.3 mo) obtained for 89% of the treated aneurysms (15 of 17) confirmed stable mean occlusion of 97.8 +/- 3.8%. Technical complications included two cases of asymptomatic distal vessel thromboembolism, which resolved angiographically within 24 hours, and one case of intraprocedural rupture of an arteriovenous malformation-related feeder artery aneurysm, which resulted in no neurological deficits and required no further treatment (transient complication rate, 13.6%; 3 of 22 cases). There were no deaths and no procedure-related 30-day or permanent morbidity. CONCLUSION: The balloon-assist method of coil embolization is characterized by promising intermediate-term angiographic and clinical outcomes and acceptable morbidity and mortality rates. Although this adjunctive method requires the use of an additional microcatheter and consequently involves a higher level of technical complexity, it extends the range of aneurysms that can be successfully treated with electrolytically detachable coils via an endovascular approach.
引用
收藏
页码:1397 / 1406
页数:10
相关论文