Variation in reported safety of lumbar interbody fusion - Influence of industrial sponsorship and other study characteristics

被引:32
作者
Fenton, Joshua J.
Mirza, Sohail K.
Lahad, Amnon
Stern, Benjamin D.
Deyo, Richard A.
机构
[1] Univ Calif Davis, Dept Family & Community Med, Sacramento, CA 95817 USA
[2] Univ Washington, Dept Orthoped Surg, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med & Hlth Serv, Seattle, WA 98195 USA
[4] Hadassah Univ Hosp, Dept Family Med, IL-91120 Jerusalem, Israel
关键词
lumbar fusion; internal fixators; postoperative complications; meta-analysis; bias; research support;
D O I
10.1097/01.brs.0000255809.95593.3b
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Systematic review. Objective. To quantify variability in undesirable outcomes among studies of lumbar interbody fusion using stand-alone cage devices, and to determine whether author conflicts of interest contribute to variability. Summary of Background Data. Promising early studies of lumbar fusion with stand-alone cage devices led to rapid uptake of the technique, but some surgeons later expressed reservations regarding efficacy and safety. Methods. We systematically identified studies of lumbar interbody fusion with stand-alone cage devices that reported at least one undesirable outcome among 10 or more adult subjects. We performed meta-analyses of rates of 7 prespecified outcomes (nonunion, reoperation, major vessel injury, retrograde ejaculation, neurologic injury, dural injury, and infection). Heterogeneity in outcome rates was quantified as I-2 (the proportion of variance due to differences among studies rather than random variation). Random-effects meta-regression identified sources of observed heterogeneity, including potential conflicts of interest. Results. We identified 30 eligible studies, including a total of 3228 subjects. A potential conflict of interest was identified in 18 (60%). We observed marked heterogeneity in rates of nonunion, reoperation, and neurologic injury (I-2 > 85%; P < 0.001), and substantial heterogeneity in rates of dural injury (I-2 = 63%; P < 0.01) and major vessel injury (I-2 = 38%; P = 0.09). Among 24 studies reporting fusion status after 6 months of follow-up, nonunion rates ranged from 2.3% to 83.3% (median, 8.3%) and exceeded 45% in 4 studies. Potential author conflict of interest was associated with significantly lower rates of nonunion (P = 0.001). Heterogeneity in rates of other undesirable outcomes was not significantly associated with author conflicts of interest or other study characteristics. Conclusion. We quantified substantial unexplained variation in reported complication rates of undesirable outcomes of lumbar interbody fusion with stand-alone cage devices. Authors with potential conflicts of interest, however, reported significantly lower rates of nonunion.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 50 条
[1]   Association of funding and conclusions in randomized drug trials - A reflection of treatment effect or adverse events? [J].
Als-Nielsen, B ;
Chen, WD ;
Gluud, C ;
Kjaergard, LL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (07) :921-928
[2]   Scope and impact of financial conflicts of interest in biomedical research - A systematic review [J].
Bekelman, JE ;
Li, Y ;
Gross, CP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (04) :454-465
[3]   A RANDOM-EFFECTS REGRESSION-MODEL FOR METAANALYSIS [J].
BERKEY, CS ;
HOAGLIN, DC ;
MOSTELLER, F ;
COLDITZ, GA .
STATISTICS IN MEDICINE, 1995, 14 (04) :395-411
[4]  
Beutler William J, 2003, Spine J, V3, P289, DOI 10.1016/S1529-9430(03)00061-5
[5]  
Bhandari M, 2004, CAN MED ASSOC J, V170, P477
[6]   The use of rhBMP-2 in interbody fusion cages - Definitive evidence of osteoinduction in humans: A preliminary report [J].
Boden, SD ;
Zdeblick, TA ;
Sandhu, HS ;
Heim, SE .
SPINE, 2000, 25 (03) :376-381
[7]   Bone morphogenetic proteins in anterior lumbar interbody fusion: old techniques and new technologies [J].
Burkus, JK .
JOURNAL OF NEUROSURGERY-SPINE, 2004, 1 (03) :254-260
[8]   Is INFUSE bone graft superior to autograft bone? An integrated analysis of clinical trials using the LT-CAGE lumbar tapered fusion device [J].
Burkus, JK ;
Heim, TE ;
Gornet, MF ;
Zdeblick, TA .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (02) :113-122
[9]   Anterior lumbar interbody fusion using rhBMP-2 with tapered interbody cages [J].
Burkus, JK ;
Gornet, MF ;
Dickman, CA ;
Zdeblick, TA .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (05) :337-349
[10]   Clinical and radiographic outcomes of anterior lumbar interbody fusion using recombinant human bone morphogenetic protein-2 [J].
Burkus, JK ;
Transfeldt, EE ;
Kitchel, SH ;
Watkins, RG ;
Balderston, RA .
SPINE, 2002, 27 (21) :2396-2408