Whole blood collected on filter paper provides a minimally invasive method for assessing human transferrin receptor level

被引:39
作者
McDade, TW [1 ]
Shell-Duncan, B
机构
[1] Northwestern Univ, Dept Anthropol, Lab Human Biol Res, Evanston, IL 60208 USA
[2] Univ Washington, Dept Anthropol, Seattle, WA 98195 USA
[3] Univ Washington, Dept Int Hlth, Seattle, WA 98195 USA
关键词
iron deficiency; transferrin receptor; blood specimen collection; immunoassay;
D O I
10.1093/jn/132.12.3760
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Iron deficiency is the most common micronutrient deficiency worldwide, and transferrin receptor (TfR) level has been identified as an important measure of iron status that is not confounded by inflammation. However, logistical constraints associated with sample collection and processing have limited efforts to measure TfR, particularly at the community level. Standardized filter paper provides a relatively convenient and minimally invasive means for collecting and transporting samples of whole blood from simple finger pricks, and we present results of our validation of an improved method for quantifying TfR in dried blood spots. The method is based on commercially available reagents and uses capillary blood that is applied directly from the finger to filter paper, eliminating the need for premeasurement at the collection site. The blood spot TfR assay is precise and reliable, agrees well with plasma TfR, and can be performed at any facility with a microplate reader and basic laboratory equipment. Concentrations of TfR remain stable for at least 4 wk when blood spots are stored at room temperature, but begin to deteriorate after 3 d of exposure to higher temperatures. The advantages and disadvantages of the blood spot TfR method are discussed, as well as its potential contribution to future field-based studies of iron deficiency.
引用
收藏
页码:3760 / 3763
页数:4
相关论文
共 19 条
[1]  
Adam BW, 2000, CLIN CHEM, V46, P126
[2]  
Allen J, 1998, CLIN CHEM, V44, P35
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   An assessment of dried blood-spot technology for identifying iron deficiency [J].
Cook, JD ;
Flowers, CH ;
Skikne, BS .
BLOOD, 1998, 92 (05) :1807-1813
[5]   SERUM TRANSFERRIN RECEPTOR [J].
COOK, JD ;
SKIKNE, BS ;
BAYNES, RD .
ANNUAL REVIEW OF MEDICINE, 1993, 44 :63-74
[6]   The measurement of serum transferrin receptor [J].
Cook, JD .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1999, 318 (04) :269-276
[7]   Rapid and simple measurement of retinol in human dried whole blood spots [J].
Erhardt, JG ;
Craft, NE ;
Heinrich, F ;
Biesalski, HK .
JOURNAL OF NUTRITION, 2002, 132 (02) :318-321
[8]  
FLOWERS CH, 1989, J LAB CLIN MED, V114, P368
[9]  
McDade TW, 2000, AM J HUM BIOL, V12, P792, DOI 10.1002/1520-6300(200011/12)12:6<792::AID-AJHB7>3.3.CO
[10]  
2-6