Evaluation of a bioceramic-based nanocomposite material for controlled delivery of a non-steroidal anti-inflammatory drug

被引:23
作者
Hesaraki, S. [1 ]
Moztarzadeh, F. [2 ]
Nezafati, N. [2 ]
机构
[1] Mat & Energy Res Ctr, Dept Ceram, Tehran 141554777, Iran
[2] Amirkabir Univ Technol, Dept Biomat, Fac Biomed Engn, Tehran, Iran
基金
美国国家科学基金会;
关键词
Calcium sulfate; Apatite; Nanocomposite; Indomethacin; Bone repair; PHOSPHATE BONE-CEMENT; IN-VITRO; CALCIUM-SULFATE; INDOMETHACIN RELEASE; APATITE CEMENT; LOCAL-DELIVERY; HYDROXYAPATITE; BIOACTIVITY; COMPOSITES; SUBSTITUTE;
D O I
10.1016/j.medengphy.2009.07.019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, nanocomposite of 50 wt% calcium sulfate and 50 wt% nanocrystalline apatite was produced and its biocompatibility, physical and structural properties were compared with pure calcium sulfate (CS) cement. Indomethacin (IM), a non-steroidal anti-inflammatory drug, was also loaded on both CS and nanocomposite cements and its in vitro release was evaluated over a period of time. The effect of the loaded IM on basic properties of the cements was also investigated. Biocompatibility tests showed a partial cytotoxicity in CS cement due to the reduced number of viable mouse fibroblast L929 cells in contact with the samples as well as spherical morphologies of the cells. However, no cytotoxic effect was observed for nanocomposite cement and no significant difference was found between the number of the cells seeded in contact with this specimens and culture plate as control. Other results showed that the setting time and injectability of the nanocomposite cement was much higher than those of CS cement, whereas reverse result obtained for compressive strength. In addition, incorporation of IM into compositions slightly increased the initial setting time and injectability of the cements and did not change their compressive strength. While a fast IM release was observed from CS cement in which about 97% of the loaded drug was released during 48 h, nanocomposite cement showed a sustained release behavior in which 80% of the loaded IM was liberated after 144 h. Thus, the nanocomposite can be a more appropriate carrier than CS for controlled release of IM in bone defect treatments. (C) 2009 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1205 / 1213
页数:9
相关论文
共 39 条
[1]   Bioactivity in glass/PMMA composites used as drug delivery system [J].
Arcos, D ;
Ragel, CV ;
Vallet-Regí, M .
BIOMATERIALS, 2001, 22 (07) :701-708
[2]  
BEESON WH, 1981, ARCH OTOLARYNGOL, V107, P664
[3]   Injectability of calcium phosphate pastes [J].
Bohner, M ;
Baroud, G .
BIOMATERIALS, 2005, 26 (13) :1553-1563
[4]   Synthesis and anaerobic biodegradation of indomethacin-conjugated cellulose ethers used for colon-specific drug delivery [J].
Cai, Xiang ;
Yang, Liqun ;
Zhang, Li-Ming ;
Wu, Qing .
BIORESOURCE TECHNOLOGY, 2009, 100 (18) :4164-4170
[5]   Assessment of acrylic bone cement as a local delivery vehicle for the application of non-steroidal anti-inflammatory drugs [J].
Corry, D ;
Moran, J .
BIOMATERIALS, 1998, 19 (14) :1295-1301
[6]   EXPERIMENTAL HYDROXYAPATITE CEMENT CRANIOPLASTY [J].
COSTANTINO, PD ;
FRIEDMAN, CD ;
JONES, K ;
CHOW, LC ;
SISSON, GA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 90 (02) :174-185
[7]   Calcium sulphate-based cements containing cephalexin [J].
Doadrio, JC ;
Arcos, D ;
Cabañas, MV ;
Vallet-Regí, M .
BIOMATERIALS, 2004, 25 (13) :2629-2635
[8]   Structure and properties of the precipitates formed from condensed solutions of the revised simulated body fluid [J].
Dorozhkina, EI ;
Dorozhkin, SV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (02) :578-581
[9]   Biomimetic calcium phosphate coatings on Polyactive® 1000/70/30 [J].
Du, C ;
Klasens, P ;
Haan, RE ;
Bezemer, J ;
Cui, FZ ;
de Groot, K ;
Layrolle, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 59 (03) :535-546
[10]   Conductive bone substitute material with variable antibiotic delivery [J].
Englert, C. ;
Angele, P. ;
Fierlbeck, J. ;
Dendorfer, S. ;
Schubert, T. ;
Mueller, R. ;
Lienhard, S. ;
Zellner, J. ;
Nerlich, M. ;
Neumann, C. .
UNFALLCHIRURG, 2007, 110 (05) :408-413