Measurement of magnetic resonance T2 for physiological experiments

被引:18
作者
Hardy, PA [1 ]
Yue, G [1 ]
机构
[1] CLEVELAND CLIN FDN,DEPT BIOMED ENGN,CLEVELAND,OH 44195
关键词
muscle activation; exercise physiology; imaging techniques;
D O I
10.1152/jappl.1997.83.3.904
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The proton transverse relaxation time (T2) of human skeletal muscles has been increasingly used in magnetic resonance imaging experiments to examine muscle physiology and neuromuscular control. However, little attention has been paid to the experimental factors affecting the accuracy or sensitivity of the T2 measurement. We have explored theoretically and experimentally the structure of several magnetic resonance pulse sequences for measuring T2 of the first dorsal interosseous muscle and found that a multiecho imaging technique using non-slice-selective refocusing pulses (MENSS) produces more accurate T2 estimates than multiecho slice-selective (MESS) imaging methods that are commonly used. Using either technique we acquired four 5-mm-thick transverse images of the first dorsal interosseous muscle with a spatial resolution of 0.6 mm within 5 min. The T2 measured by the MENSS method was closer to the true T2 than was the T2 estimated by the MESS method. After a given amount of exercise, the MENSS technique revealed an average 28 +/- 10% increase in T2 compared with a 13 +/- 3% increase measured with an equivalent MESS technique. We conclude that the MENSS method is a more accurate and sensitive procedure for studying neuromuscular physiology compared with the more commonly used MESS method.
引用
收藏
页码:904 / 911
页数:8
相关论文
共 23 条
[1]   MAGNETIC-RESONANCE-IMAGING AND ELECTROMYOGRAPHY AS INDEXES OF MUSCLE FUNCTION [J].
ADAMS, GR ;
DUVOISIN, MR ;
DUDLEY, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (04) :1578-1589
[2]   MAPPING OF ELECTRICAL MUSCLE STIMULATION USING MRI [J].
ADAMS, GR ;
HARRIS, RT ;
WOODARD, D ;
DUDLEY, GA .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (02) :532-537
[3]   IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION [J].
BERNSTEIN, MA ;
THOMASSON, DM ;
PERMAN, WH .
MEDICAL PHYSICS, 1989, 16 (05) :813-817
[4]  
Bevington R., 1969, DATA REDUCTION ERROR
[5]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[6]   DYNAMIC EVALUATION OF EXERCISING LEG MUSCLE IN HEALTHY-SUBJECTS WITH ECHO-PLANAR MR-IMAGING - WORK RATE AND TOTAL WORK DETERMINE RATE OF T2 CHANGE [J].
DISLER, DG ;
COHEN, MS ;
KREBS, DE ;
ROY, SH ;
ROSENTHAL, DI .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (05) :588-593
[7]  
ENGLISH AE, 1992, MAGNET RESON MED, V22, P425
[8]   DIRECT RELATIONSHIP BETWEEN PROTON T2 AND EXERCISE INTENSITY IN SKELETAL-MUSCLE MR IMAGES [J].
FISHER, MJ ;
MEYER, RA ;
ADAMS, GR ;
FOLEY, JM ;
POTCHEN, EJ .
INVESTIGATIVE RADIOLOGY, 1990, 25 (05) :480-485
[9]   ACUTE EFFECTS OF EXERCISE ON MR IMAGING OF SKELETAL-MUSCLE IN NORMAL VOLUNTEERS [J].
FLECKENSTEIN, JL ;
CANBY, RC ;
PARKEY, RW ;
PESHOCK, RM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) :231-237
[10]   FINGER-SPECIFIC FLEXOR RECRUITMENT IN HUMANS - DEPICTION BY EXERCISE-ENHANCED MRI [J].
FLECKENSTEIN, JL ;
WATUMULL, D ;
BERTOCCI, LA ;
PARKEY, RW ;
PESHOCK, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 72 (05) :1974-1977