Polyurethane heart valve durability: effects of leaflet thickness and material

被引:34
作者
Bernacca, GM
Mackay, TG
Gulbransen, MJ
Donn, AW
Wheatley, DJ
机构
[1] Univ. Department of Cardiac Surgery, Glasgow Roy. Infirm. Univ. NHS Trust, Glasgow
[2] Univ. Department of Cardiac Surgery, Royal Infirmary, Glasgow G31 2ER
关键词
polyurethane; prosthetic heart valve; durability;
D O I
10.1177/039139889702000606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A flexible trileaflet polyurethane valve has been made by dip-moulding leaflets directly onto an injection-moulded frame. The durability of this valve is, in part, determined by the thickness of ifs leaflets. Leaflet thickness is also a major determinant of hydrodynamic function. This study examines valves (n = 31) with leaflets made of a polyetherurethane (PEU, n = 22) or a polyetherurethaneurea (PEUE, n = 9), of varying thickness distributions. The valves were subjected to accelerated fatigue test at 37 degrees C and failure monitored. Leaflet thicknesses ranged from 60 to 200 mu m. PEU leaflet thickness bore no relationship to durability which was less than 400 million cycles. PEUE valves, in contrast exceeded 800 million cycles. Durability in PEUE valves was directly related to leaflet thickness (r = 0.93, p < 0.001), with good durability achieved with median leaflet thicknesses Of approximately 150 mu m. Thus polyurethane valves can be made with good hydrodynamic properties and with sufficient durability to consider potential clinical use.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 15 条
  • [1] Bernacca G M, 1992, J Heart Valve Dis, V1, P115
  • [2] A DYNAMIC INVITRO METHOD FOR STUDYING BIOPROSTHETIC HEART-VALVE CALCIFICATION
    BERNACCA, GM
    FISHER, AC
    MACKAY, TG
    WHEATLEY, DJ
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (04) : 293 - 298
  • [3] Bernacca GM, 1997, J BIOMED MATER RES, V34, P371
  • [4] CALCIFICATION AND FATIGUE FAILURE IN A POLYURETHANE HEART-VALVE
    BERNACCA, GM
    MACKAY, TG
    WILKINSON, R
    WHEATLEY, DJ
    [J]. BIOMATERIALS, 1995, 16 (04) : 279 - 285
  • [5] Bernacca GM, 1996, J HEART VALVE DIS, V5, P538
  • [6] CALCIFICATION MODELING IN ARTIFICIAL-HEART VALVES
    FISHER, AC
    BERNACCA, GM
    MACKAY, TG
    DIMITRI, WR
    WILKINSON, R
    WHEATLEY, DJ
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (05) : 284 - 288
  • [7] Ghista D. N., 1983, ADV CARDIOVASCULAR 4, V5, P31
  • [8] GIDDENS DP, 1993, CARDIOVASC PATHOL, V2, pS167
  • [9] SELECTED TOPICS IN BIOMEDICAL POLYURETHANES - A REVIEW
    GOGOLEWSKI, S
    [J]. COLLOID AND POLYMER SCIENCE, 1989, 267 (09) : 757 - 785
  • [10] HILBERT SL, 1987, J THORAC CARDIOV SUR, V94, P419