Extent of cardiac sympathetic neuronal damage is determined by the area of ischemia in patients with acute coronary syndromes

被引:136
作者
Matsunari, I
Schricke, U
Bengel, FM
Haase, HU
Barthel, P
Schmidt, G
Nekolla, SG
Schoemig, A
Schwaiger, M
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Nukl Med Klin & Poliklin, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-81675 Munich, Germany
关键词
nervous system; autonomic; coronary disease; tomography;
D O I
10.1161/01.CIR.101.22.2579
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Prior studies have demonstrated that acute ischemic injury causes sympathetic neuronal damage exceeding the area of necrosis. The aim of this study was to test the hypothesis that sympathetic neuronal damage measured by I-123-metaiodobenzylguanidine (MIBG) imaging would be determined by the area of ischemia as reflected by area at risk in patients undergoing reperfusion therapy for acute coronary syndromes. Methods and Results-In 12 patients, the myocardium at risk was assessed by Tc-99m sestamibi SPECT before reperfusion, and infarct size was measured by follow-up Tc-99m-sestamibi SPECT 1 week later. All patients also underwent I-123-MIBG SPECT within a mean of Il days after onset. The SPECT image analysis was based on a semiquantitative polar map approach. Defect size on the I-123-MIBG or Tc-99m-sestamibi SPECT was measured for the left ventricle (LV) with the use of a threshold of -2.5 SD from the mean value of a normal database and was expressed as %LV. The I-123-MIBG defect size (47 +/- 18%LV) was larger than the infarct size (27 +/- 23%LV, P<0.001) but was similar to the risk area (49 +/- 18%LV, P=NS). Furthermore, the I-123-MIBG defect size was closely correlated with the risk area (r=0.905, P<0.001). Conclusions-Sympathetic neuronal damage measured by I-123-MIBG SPECT is larger than infarct size and is closely related to risk area, suggesting high sensitivity of neuronal structures to ischemia compared with myocardial cells.
引用
收藏
页码:2579 / 2585
页数:7
相关论文
共 25 条
[1]   Carbon-11 Hydroxyephedrine With Positron Emission Tomography for Serial Assessment of Cardiac Adrenergic Neuronal Function After Acute Myocardial Infarction in Humans [J].
Allman, Kevin C. ;
Wieland, Donald M. ;
Muzik, Otto ;
Degrado, Timothy R. ;
Wolfe, Edwin R., Jr. ;
Schwaiger, Markus .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :368-375
[2]   TRANSMURAL MYOCARDIAL-INFARCTION IN THE DOG PRODUCES SYMPATHECTOMY IN NON-INFARCTED MYOCARDIUM [J].
BARBER, MJ ;
MUELLER, TM ;
HENRY, DP ;
FELTEN, SY ;
ZIPES, DP .
CIRCULATION, 1983, 67 (04) :787-796
[3]   NONINVASIVE IDENTIFICATION OF MYOCARDIUM AT RISK IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION AND NONDIAGNOSTIC ELECTROCARDIOGRAMS WITH TECHNETIUM-99M-SESTAMIBI [J].
CHRISTIAN, TF ;
CLEMENTS, IP ;
GIBBONS, RJ .
CIRCULATION, 1991, 83 (05) :1615-1620
[4]   SCINTIGRAPHIC ASSESSMENT OF SYMPATHETIC INNERVATION AFTER TRANSMURAL VERSUS NONTRANSMURAL MYOCARDIAL-INFARCTION [J].
DAE, MW ;
HERRE, JM ;
OCONNELL, JW ;
BOTVINICK, EH ;
NEWMAN, D ;
MUNOZ, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) :1416-1423
[5]   Heterogeneous sympathetic innervation in German shepherd dogs with inherited ventricular arrhythmia and sudden cardiac death [J].
Dae, MW ;
Lee, RJ ;
Ursell, PC ;
Chin, MC ;
Stillson, CA ;
Moise, NS .
CIRCULATION, 1997, 96 (04) :1337-1342
[6]  
DAE MW, 1992, J NUCL MED, V33, P1444
[7]   Optimal collimator choice for sequential iodine-123 and technetium-99m imaging [J].
DeGeeter, F ;
Franken, PR ;
Defrise, M ;
Andries, H ;
Saelens, E ;
Bossuyt, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (07) :768-774
[8]   FEASIBILITY OF TOMOGRAPHIC TC-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL AREA AT RISK AND THE EFFECT OF TREATMENT IN ACUTE MYOCARDIAL-INFARCTION [J].
GIBBONS, RJ ;
VERANI, MS ;
BEHRENBECK, T ;
PELLIKKA, PA ;
OCONNOR, MK ;
MAHMARIAN, JJ ;
CHESEBRO, JH ;
WACKERS, FJ .
CIRCULATION, 1989, 80 (05) :1277-1286
[9]   HETEROGENEITY OF THE HUMAN MYOCARDIAL SYMPATHETIC INNERVATION - IN-VIVO DEMONSTRATION BY IODINE-123-LABELED METAIODOBENZYLGUANIDINE SCINTIGRAPHY [J].
GILL, JS ;
HUNTER, GJ ;
GANE, G ;
CAMM, AJ .
AMERICAN HEART JOURNAL, 1993, 126 (02) :390-398
[10]   VIABILITY THRESHOLDS AND THE PENUMBRA OF FOCAL ISCHEMIA [J].
HOSSMANN, KA .
ANNALS OF NEUROLOGY, 1994, 36 (04) :557-565