Aortic input impedance in infants and children

被引:29
作者
Sharp, MK
Pantalos, GM
Minich, L
Tani, LY
McGough, EC
Hawkins, JA
机构
[1] Univ Utah, Dept Bioengn, Biofluid Mech Lab, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Surg, Salt Lake City, UT 84112 USA
[3] Primary Childrens Med Ctr, Dept Pediat, Div Cardiol, Salt Lake City, UT 84113 USA
[4] Primary Childrens Med Ctr, Dept Surg, Div Cardiothorac Surg, Salt Lake City, UT 84113 USA
关键词
flow; pressure; resistance; compliance;
D O I
10.1152/jappl.2000.88.6.2227
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit weight was relatively constant but was approximately three times higher than for adults. Strong inertial character was observed in the impedance of four of the six patients. Among a three-element and two four-element lumped-parameter models, the model with characteristic aortic resistor (R-c) and inertance in series followed by parallel peripheral resistor (R-p) and compliance fitted the data best. R, decreased with increasing patient weight and was one to three times higher than in adults, and R, decreased with increasing patient weight and was 2 to 15 times higher. The R-p-to-R-c ratio differed significantly between infants and children vs. adults. The results suggested that R, developed more rapidly with patient weight than did R,. Compliance values increased with increasing patient weight and were 3 to 16 times lower than adult values.
引用
收藏
页码:2227 / 2239
页数:13
相关论文
共 18 条
[1]   ASSESSMENT OF WINDKESSEL AS A MODEL OF AORTIC INPUT IMPEDANCE [J].
BURKHOFF, D ;
ALEXANDER, J ;
SCHIPKE, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (04) :H742-H753
[2]  
FRANK D, 1899, Z BIOLOGIE, V37, P483
[3]   MEASUREMENT OF INPUT IMPEDANCE + APPARENT PHASE VELOCITY IN HUMAN AORTA [J].
GABE, IT ;
RUDEWALD, B ;
KARNELL, J ;
PORJE, IG .
ACTA PHYSIOLOGICA SCANDINAVICA, 1964, 61 (1-2) :73-&
[4]  
LIU Z, 1986, AM J PHYSIOL, V251, P588
[5]   PRESSURE-FLOW RELATIONSHIPS AND VASCULAR IMPEDANCE IN MAN [J].
MILLS, CJ ;
GABE, IT ;
GAULT, JH ;
MASON, DT ;
ROSS, J ;
BRAUNWAL.E ;
SHILLING.JP .
CARDIOVASCULAR RESEARCH, 1970, 4 (04) :405-&
[6]   AORTIC WAVELENGTH AS A DETERMINANT OF THE RELATION BETWEEN HEART-RATE AND BODY SIZE IN MAMMALS [J].
MILNOR, WR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (01) :R3-R6
[7]   AORTIC INPUT IMPEDANCE IN NORMAL MAN - RELATIONSHIP TO PRESSURE WAVE FORMS [J].
MURGO, JP ;
WESTERHOF, N ;
GIOLMA, JP ;
ALTOBELLI, SA .
CIRCULATION, 1980, 62 (01) :105-116
[8]   INPUT IMPEDANCE OF SYSTEMIC CIRCULATION IN MAN [J].
NICHOLS, WW ;
CONTI, CR ;
WALKER, WE ;
MILNOR, WR .
CIRCULATION RESEARCH, 1977, 40 (05) :451-458
[9]   PULSATILE FLOW AND PRESSURE IN HUMAN SYSTEMIC ARTERIES - STUDIES IN MAN AND IN A MULTIBRANCHED MODEL OF THE HUMAN SYSTEMIC ARTERIAL TREE [J].
OROURKE, MF ;
AVOLIO, AP .
CIRCULATION RESEARCH, 1980, 46 (03) :363-372
[10]   Estimation of timing errors for the intraaortic balloon pump use in pediatric patients [J].
Pantalos, GM ;
Minich, LL ;
Tani, LY ;
McGough, EC ;
Hawkins, JA .
ASAIO JOURNAL, 1999, 45 (03) :166-171