Application of sonomicrometry and multidimensional scaling to cardiac catheter tracking

被引:15
作者
Meyer, SA
Wolf, PD
机构
[1] Department of Biomédical Engineering, Duke University, Box 90281, Durham
[2] Department of Biomédical Engineering, Duke University, Durham
关键词
cardiac catheter; multidimensional scaling; sonomicrometry; tracking;
D O I
10.1109/10.641333
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a technique for tracking the three-dimensional (3-D) position of a cardiac catheter using sonomicrometry and the mathematical method of multidimensional scaling (MDS). Sonomicrometry is used to measure the distances between ultrasonic transceivers. MDS is then used to calculate the 3-D coordinates of the ultrasonic transceiver locations, including the catheter tip, from the measured distances. Feasibility of catheter tracking was initially studied using simulated data from a geometric model in which the actual coordinates of all transceivers were known. The method was then shown to be feasible in vivo by tracking a catheter-mounted piezoelectric transducer using seven reference crystals sewn to the epicardial surface of a sheep heart. Simulation results indicate that a catheter can be tracked with a root-mean-square (rms) error of 1.51 +/- 0.05 mm and an average-distance error of e = 1.06 +/- 0.27 mm using 12 reference points. In vivo results showed acceptable stress values (G < 0.05) for 95% of the data samples with an average-distance error of e = 0.52 +/- 0.66 mm. These simulation and experimental results show that sonomicrometry and MDS can be used to accurately localize the 3-D position and track the motion of a catheter tip within the heart.
引用
收藏
页码:1061 / 1067
页数:7
相关论文
共 12 条
[1]  
BENHAIM SA, 1996, PACING CLIN ELECTR 2, V19, P709
[2]  
Borg I., 1987, Multidimensional Similarity Structure Analysis
[3]  
Christensen D., 1988, ULTRASONIC BIOINSTRU
[4]  
Gardner E., 1975, ANATOMY REGIONAL STU
[5]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[6]   ENDOCARDIAL CATHETER MAPPING - VALIDATION OF A CINERADIOGRAPHIC METHOD FOR ACCURATE LOCALIZATION OF LEFT-VENTRICULAR SITES [J].
HAUER, RNW ;
HEETHAAR, RM ;
DEZWART, MTW ;
VANDIJK, RN ;
VANDERTWEEL, I ;
BORST, C ;
DEMEDINA, EOR .
CIRCULATION, 1986, 74 (04) :862-868
[7]   USE OF SONOMICROMETRY AND MULTIDIMENSIONAL-SCALING TO DETERMINE THE 3-DIMENSIONAL COORDINATES OF MULTIPLE CARDIAC LOCATIONS - FEASIBILITY AND INITIAL IMPLEMENTATION [J].
RATCLIFFE, MB ;
GUPTA, KB ;
STREICHER, JT ;
SAVAGE, EB ;
BOGEN, DK ;
EDMUNDS, LH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) :587-598
[8]  
SMEETS J, 1996, PACING CLIN ELECTROP, V19, P627
[9]  
SPENCER R, 1986, BYTE, V11, P85
[10]  
YEE R, 1994, CARDIAC ELECTROPHYSI, P1199