Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique

被引:29
作者
Dos Remedios, C. [1 ]
Nebout, J. [1 ]
Benlarbi, H. [1 ]
Caremier, E. [1 ]
Sam-Wing, J. -F. [1 ]
Beya, R. [1 ]
机构
[1] Ctr Hosp La Rochelle, Serv Chirurg Orthoped, F-17019 La Rochelle, France
关键词
Radius; Palmar plate; Pronator quadratus; COMPLICATIONS;
D O I
10.1016/j.main.2009.04.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Introduction. - A surgical technique is described to preserve the pronator quadratus muscle when fixing distal radius fractures with volar locking palmar plates. Technique. - Using a classic volar Henry approach to the wrist, the fibrous distal attachments of the pronator quadratus muscle are released. The locking palmar plate is passed under the pronator quadratus muscle and its correct placement is checked by fluoroscopy. Locking screws are inserted through mini-incisions in pronator quadratus. Discussion. - The pronator quadratus muscle plays an important role in wrist function, both in forearm pronation and as a stabilizer of the distal radioulnar joint. Mechanical impingement between the volar plate and the flexor tendons can cause adherences, ruptures and tenosynovitis. These should be reduced if pronator quadratus were intact. Conclusion. - Preservation of the pronator quadratus muscle is possible for the majority of the fractures of the distal radius treated with locking volar plate osteosynthesis. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 10 条
[1]
Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[2]
Duncan Scott F M, 2007, Am J Orthop (Belle Mead NJ), V36, P669
[3]
Pronator quadratus repair using the Henry approach with an outward-return running suture [J].
Erhard, L. ;
farah, C. Bou ;
Elkholti, K. ;
Ninou, M. ;
Rostoucher, P. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (04) :381-384
[4]
Henry AK, 1973, EXTENSILE EXPOSURE
[5]
Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius [J].
Imatani, J ;
Noda, T ;
Morito, Y ;
Sato, T ;
Hashizume, H ;
Inoue, H .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (02) :220-225
[6]
Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture? a biomechanical study [J].
Kandemir, Utku ;
Matityahu, Amir ;
Desai, Rohan ;
Puttlitz, Christian .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) :605-610
[7]
Volar fixed angle plate LCP 3.5® for dorsally distal radius fracture.: About 24 cases [J].
Pichon, H. ;
Chergaoui, A. ;
Jager, S. ;
Carpentier, E. ;
Jourdel, F. ;
Chaussard, C. ;
Saragaglia, D. .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (02) :152-159
[8]
Rampold M, 2007, ACTA ORTHOP BELG, V73, P714
[9]
Pronator quadratus revisited [J].
Stuart, PR .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1996, 21B (06) :714-722
[10]
TOBE M, 2006, REV CHIR MANO, V3, P280