Use of human immunodeficiency virus (HIV) type 1 and 2 recombinant strip immunoblot assay to resolve enzyme immunoassay anti-HIV-2-repeatably reactive samples after anti-HIV-1/2 combination enzyme immunoassay screening

被引:5
作者
Tobler, LH
Kaufman, E
Gefter, N
Schable, C
Busch, MP
机构
[1] UNIV CALIF SAN FRANCISCO,SAN FRANCISCO,CA 94143
[2] CHIRON CORP,IMMUNODIAGNOST DEV,EMERYVILLE,CA 94608
[3] CTR DIS CONTROL & PREVENT,SEROL SECT,DIV AIDS STD & TB LAB RES,ATLANTA,GA
[4] IRWIN MEM BLOOD CTR,RES SERV,SAN FRANCISCO,CA 94118
关键词
D O I
10.1046/j.1537-2995.1997.37997454018.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: With the implementation of combination human immunodeficiency virus types 1 and 2 (HIV-1/2) antibody enzyme immunoassay (EIA) in donor screening in 1992, the supplemental testing algorithm changed to require the use of a Food and Drug Administration (FDA)-licensed HIV-1 Western blot (WB) or immunofluorescence assay, as well as an FDA-licensed HIV-2 EIA. When HIV-2 EIA-reactive specimens are identified, further testing to confirm HIV-2 infection is recommended. Currently, a licensed HIV-2 supplemental assay is not available. STUDY DESIGN AND METHODS: The sensitivity of an HIV-1/2 recombinant strip immunoblot assay (SIA) for HIV-2 was determined on the basis of the analysis of 65 HIV-2-positive samples identified by the Centers for Disease Control and Prevention (CDC). Anti-HIV-1/2 combination EIA-repeatably reactive (RR) specimens from seven blood centers and their affiliated hospitals were tested in parallel by HIV-1 WE and HIV-2 EIA. Anti-HIV-2 EIA-RR specimens were further tested by HIV-1/2 SIA. Specimens interpreted as positive for HIV-2 or HIV-1/2 were referred to the CDC for final resolution of antibody status. RESULTS: Ninety-seven percent (63/65) of known HIV-2-positive samples tested positive for HIV-2 only or HIV-1/2 on the HIV-1/2 SIA. A total of 1048 anti-HIV-1/2 combination-EIA-RR specimens were evaluated. Sixty-nine percent (75/109) of the WB-positive specimens were HIV-2 EIA-RR, while only 9 percent (84/939) of WB-indeterminate or WB-negative specimens tested HIV-2 EIA-RR. The HIV-1/2 SIA resolved 91 percent of HIV-2 EIA-RR samples as negative. Four HIV-2 EIA-RR specimens (all HIV-1 WB-positive) were classified as positive for HIV-I and HIV-2 in the HIV-1/2 SIA. Final interpretation of these specimens by CDC was that they were reactive for HIV-1 with cross-reactivity to HIV-2. CONCLUSION: No confirmed HIV-2-positive specimens were detected. The HIV-1/2 SIA is currently useful for resolving HIV-2 EIA-RR specimens.
引用
收藏
页码:921 / 925
页数:5
相关论文
共 19 条
[1]  
Busch Michael P., 1994, P224
[2]   Frequency of human immunodeficiency virus (HIV) infection among contemporary anti-HIV-1 and anti-HIV-1/2 supplemental test-indeterminate blood donors [J].
Busch, MP ;
Kleinman, SH ;
Williams, AE ;
Smith, JW ;
Ownby, HE ;
Laycock, ME ;
Lee, LLL ;
Pau, CP ;
Schreiber, GB .
TRANSFUSION, 1996, 36 (01) :37-44
[3]   To thy (reactive) donors be true! [J].
Busch, MP .
TRANSFUSION, 1997, 37 (02) :117-120
[4]   CONTINUED MONITORING FOR HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-2 INFECTIONS IN CALIFORNIA [J].
BUSCH, MP ;
TOBLER, L ;
SCHABLE, C ;
PETERSEN, L .
TRANSFUSION, 1992, 32 (09) :873-873
[5]  
CABRIAN K, 1988, J CLIN IMMUNOASSAY, V11, P107
[6]   ANTI-HEPATITIS-C VIRUS (ANTI-HCV) SEROCONVERSION IN PATIENTS UNDERGOING HEMODIALYSIS - COMPARISON OF 2ND-GENERATION AND 3RD-GENERATION ANTI-HCV ASSAYS [J].
COUROUCE, AM ;
LEMARREC, N ;
GIRAULT, A ;
DUCAMP, S ;
SIMON, N .
TRANSFUSION, 1994, 34 (09) :790-795
[7]  
*FDA CTR BIOL EV R, 1992, REV REC PREV HUM IMM
[8]   EFFICACIES OF UNITED-STATES-FOOD-AND-DRUG-ADMINISTRATION-LICENSED HIV-1-SCREENING ENZYME IMMUNOASSAYS FOR DETECTING ANTIBODIES TO HIV-2 [J].
GEORGE, JR ;
RAYFIELD, MA ;
PHILLIPS, S ;
HEYWARD, WL ;
KREBS, JW ;
ODEHOURI, K ;
SOUDRE, R ;
DECOCK, KM ;
SCHOCHETMAN, G .
AIDS, 1990, 4 (04) :321-326
[9]   GENOME ORGANIZATION AND TRANSACTIVATION OF THE HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-2 [J].
GUYADER, M ;
EMERMAN, M ;
SONIGO, P ;
CLAVEL, F ;
MONTAGNIER, L ;
ALIZON, M .
NATURE, 1987, 326 (6114) :662-669
[10]   THE GLOBAL DISTRIBUTION OF HUMAN IMMUNODEFICIENCY VIRUS TYPE-2 (HIV-2) INFECTION [J].
HORSBURGH, CR ;
HOLMBERG, SD .
TRANSFUSION, 1988, 28 (02) :192-195