Incorporating prior knowledge into beam orientaton optimization in IMRT

被引:104
作者
Pugachev, A [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 54卷 / 05期
关键词
IMRT; inverse planning; intensity modulation; optimization; beam orientation;
D O I
10.1016/S0360-3016(02)03917-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Selection of beam configuration in currently available intensity-modulated radiotherapy (IMRT) treatment planning systems is still based on trial-and-error search. Computer beam orientation optimization has the potential to improve the situation, but its practical implementation is hindered by the excessive computing time associated with the calculation. The purpose of this work is to provide an effective means to speed up the beam orientation optimization by incorporating a priori geometric and dosimetric knowledge of the system and to demonstrate the utility of the new algorithm for beam placement in IMRT. Methods and Materials: Beam orientation optimization was performed in two steps. First, the quality of each possible beam orientation was evaluated using beam's-eye-view dosimetrics (BEVD) developed in our previous study. A simulated annealing algorithm was then employed to search for the optimal set of beam orientations, taking into account the BEVD scores of different incident beam directions. During the calculation, sampling of gantry angles was weighted according to the BEVD score computed before the optimization. A beam direction with a higher BEVD score had a higher probability of being included in the trial configuration, and vice versa. The inclusion of the BEVD weighting in the stochastic beam angle sampling process made it possible to avoid spending valuable computing time unnecessarily at "bad" beam angles. An iterative inverse treatment planning algorithm was used for beam intensity profile optimization during the optimization process. The BEVD-guided beam orientation optimization was applied to an IMRT treatment of paraspinal tumor. The advantage of the new optimization algorithm was demonstrated by comparing the calculation with the conventional scheme without the BEVD weighting in the beam sampling. Results: The BEVD tool provided useful guidance for the selection of the potentially good directions for the beams to incident and was used to guide the search for the optimal beam configuration. The BEVD-guided sampling improved both optimization speed and convergence of the calculation. A comparison of several five-field IMRT treatment plans obtained with and without BEVD guidance indicated that the computational efficiency was increased by a factor of similar to10. Conclusion: Incorporation of BEVD information allows for development of a more robust tool for beam orientation optimization in IMRT planning. It enables us to more effectively use the angular degree of freedom in IMRT without paying the excessive computing overhead and brings us one step closer to the goal of automated selection of beam orientations in a clinical environment. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1565 / 1574
页数:10
相关论文
共 38 条
[1]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[2]   THE USE OF BEAM EYE VIEW VOLUMETRICS IN THE SELECTION OF NONCOPLANAR RADIATION PORTALS [J].
CHEN, GTY ;
SPELBRING, DR ;
PELIZZARI, CA ;
BALTER, JM ;
MYRIANTHOPOULOS, LC ;
VIJAYAKUMAR, S ;
HALPERN, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (01) :153-163
[3]   Optimization of intensity modulated beams with volume constraints using two methods: Cost function minimization and projections onto convex sets [J].
Cho, PS ;
Lee, S ;
Marks, RJ ;
Oh, SH ;
Sutlief, SG ;
Phillips, MH .
MEDICAL PHYSICS, 1998, 25 (04) :435-443
[4]   A multiobjective gradient-based dose optimization algorithm for external beam conformal radiotherapy [J].
Cotrutz, C ;
Lahanas, M ;
Kappas, C ;
Baltas, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) :2161-2175
[5]   Multiple local minima in radiotherapy optimization problems with dose-volume constraints [J].
Deasy, JO .
MEDICAL PHYSICS, 1997, 24 (07) :1157-1161
[6]  
GOPAL R, 2001, MED PHYS, V28, P1227
[7]   Optimization of beam orientation in radiotherapy using planar geometry [J].
Haas, OCL ;
Burnham, KJ ;
Mills, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2179-2193
[8]   OPTIMIZATION BY SIMULATED ANNEALING [J].
KIRKPATRICK, S ;
GELATT, CD ;
VECCHI, MP .
SCIENCE, 1983, 220 (4598) :671-680
[9]   Clinical implementation of wedge filter optimization in three-dimensional radiotherapy treatment planning [J].
Li, JG ;
Boyer, AL ;
Xing, L .
RADIOTHERAPY AND ONCOLOGY, 1999, 53 (03) :257-264
[10]  
LLACER J, 2002, UNPUB PHYS MED BIOL