Transient pumping of a Ni-like Ag x-ray laser with a subpicosecond pump pulse in a traveling-wave irradiation geometry

被引:64
作者
Klisnick, A
Zeitoun, P
Ros, D
Carillon, A
Fourcade, P
Hubert, S
Jamelot, G
Lewis, CLS
Mac Phee, AG
O'Rourcke, RMN
Keenan, R
Nickles, PV
Janulewicz, K
Kalashnikov, M
Warwick, J
Chanteloup, JC
Migus, A
Salmon, E
Sauteret, C
Zou, JP
机构
[1] Univ Paris Sud, Lab Spectroscopie Atom & Ion, F-91405 Orsay, France
[2] Queens Univ Belfast, Sch Math & Phys, Belfast BT7 1NN, Antrim, North Ireland
[3] Ecole Polytech, Lab Utilisat Lasers Intenses, F-91128 Palaiseau, France
[4] Max Born Inst, D-12489 Berlin, Germany
关键词
D O I
10.1364/JOSAB.17.001093
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.
引用
收藏
页码:1093 / 1097
页数:5
相关论文
共 17 条
  • [1] Afanas'ev Yu. V., 1989, Soviet Journal of Quantum Electronics, V19, P1606, DOI 10.1070/QE1989v019n12ABEH009835
  • [2] Using low and high prepulses to enhance the J=0-1 transition at 19.6 nm in the Ne-like germanium XUV laser
    Cairns, GF
    Lewis, CLS
    Lamb, MJ
    MacPhee, AG
    Neely, D
    Norreys, P
    Key, MH
    Healy, SB
    Holden, PB
    Pert, GJ
    Plowes, JA
    Tallents, GJ
    Demir, A
    [J]. OPTICS COMMUNICATIONS, 1996, 123 (4-6) : 777 - 789
  • [3] Pulse-front control of 15-TW pulses with a tilted compressor, and application to the subpicosecond traveling-wave pumping of a soft-x-ray laser
    Chanteloup, JC
    Salmon, E
    Sauteret, C
    Migus, A
    Zeitoun, P
    Klisnick, A
    Carillon, A
    Hubert, S
    Ros, D
    Nickles, P
    Kalachnikov, M
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (01) : 151 - 157
  • [4] EFFICIENT SOFT-X-RAY LASING AT 6 TO 8 NM WITH NICKEL-LIKE LANTHANIDE IONS
    DAIDO, H
    KATO, Y
    MURAI, K
    NINOMIYA, S
    KODAMA, R
    YUAN, G
    OSHIKANE, Y
    TAKAGI, M
    TAKABE, H
    KOIKE, F
    [J]. PHYSICAL REVIEW LETTERS, 1995, 75 (06) : 1074 - 1077
  • [5] DASILVA LB, 1993, SPIE, V2012, P158
  • [6] Demonstration of x-ray amplification in transient gain nickel-like palladium scheme
    Dunn, J
    Osterheld, AL
    Shepherd, R
    White, WE
    Shlyaptsev, VN
    Stewart, RE
    [J]. PHYSICAL REVIEW LETTERS, 1998, 80 (13) : 2825 - 2828
  • [7] Saturated operation of a transient collisional x-ray laser
    Kalachnikov, MP
    Nickles, PV
    Schnurer, M
    Sandner, W
    Shlyaptsev, VN
    Danson, C
    Neely, D
    Wolfrum, E
    Zhang, J
    Behjat, A
    Demir, A
    Tallents, GJ
    Warwick, PJ
    Lewis, CLS
    [J]. PHYSICAL REVIEW A, 1998, 57 (06): : 4778 - 4783
  • [8] KATO Y, 1999, IOP C SERIES, V159
  • [9] Klisnick A, 1999, INST PHYS CONF SER, V159, P107
  • [10] MacPhee A.G., 1996, INST PHYS CONF SE, V151, P250