Evaluation of a standard breast tangent technique: A dose-volume analysis of tangential irradiation using three dimensional tools

被引:67
作者
Krasin, M
McCall, A
King, S
Olson, M
Emami, B
机构
[1] Loyola Univ, Med Ctr, Dept Radiotherapy, Maywood, IL 60153 USA
[2] Provena St Josephs Med Ctr, Dept Radiotherapy, Joliet, IL USA
[3] Loyola Univ, Med Ctr, Dept Radiol, Maywood, IL 60153 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 47卷 / 02期
关键词
breast cancer; 2D treatment; tangential irradiation; dose-volume analysis;
D O I
10.1016/S0360-3016(00)00449-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A thorough dose-volume analysis of a standard tangential radiation technique has not been published. We evaluated the adequacy of a tangential radiation technique in delivering dose to the breast and regional lymphatics, as well as dose delivered to underlying critical structures. Methods and Materials: Treatment plans of 25 consecutive women with breast cancer undergoing lumpectomy and adjuvant-breast radiotherapy were studied, Patients underwent two-dimensional (2D) treatment planning followed by treatment with standard breast tangents. These 2D plans were reconstructed without modification on our three-dimensional treatment planning system and analyzed with regard to dose-volume parameters. Results: Adequate coverage of the breast (defined as 95% of the target receiving at least 95% of the prescribed dose) was achieved in 16 of 25 patients, with all patients having at least 85% of the breast volume treated to 95% of the prescribed dose. Only 1 patient (4%) had adequate coverage of the Level I axilla, and no patient had adequate coverage of the Level II axilla, Level III axilla, or the internal mammary lymph nodes. Conclusion: Three-dimensional treatment planning is superior in quantification of the dose received by the breast, regional lymphatics, and critical structures. The standard breast tangent technique delivers an adequate dose to the breast but does not therapeutically treat the regional lymph nodes in the majority of patients. If coverage of the axilla or internal mammary lymph nodes is desired, alternate beam arrangements or treatment fields will be necessary, (C) 2000 Elsevier Science Inc.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 42 条
[1]   Axillary lymph node metastases: Screening with [F-18]2-deoxy-2-fluoro-D-glucose (FDG) PET [J].
Adler, LP ;
Faulhaber, PF ;
Schnur, KC ;
AlKasi, NL ;
Shenk, RR .
RADIOLOGY, 1997, 203 (02) :323-327
[2]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[3]   Variability of the location of internal mammary vessels and glandular breast tissue in breast cancer patients undergoing routine CT-based treatment planning [J].
Bentel, G ;
Marks, LB ;
Hardenbergh, P ;
Prosnitz, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1017-1025
[4]  
Blichert-Toft M, 1992, J Natl Cancer Inst Monogr, P19
[5]  
Botnick M, 1998, INT J RADIAT ONCOL, V42, P245
[6]   Dosimetric analysis of intact breast irradiation in off-axis planes [J].
Buchholz, TA ;
Gurgoze, E ;
Bice, WS ;
Prestidge, BR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :261-267
[7]   Impact of setup variability on incidental lung irradiation during tangential breast treatment [J].
Carter, DL ;
Marks, LB ;
Bentel, GC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :109-115
[8]   RANDOMIZED CLINICAL-TRIAL TO ASSESS THE EFFECTIVENESS OF BREAST IRRADIATION FOLLOWING LUMPECTOMY AND AXILLARY DISSECTION FOR NODE-NEGATIVE BREAST-CANCER [J].
CLARK, RM ;
MCCULLOCH, PB ;
LEVINE, MN ;
LIPA, M ;
WILKINSON, RH ;
MAHONEY, LJ ;
BASRUR, VR ;
NAIR, BD ;
MCDERMOT, RS ;
WONG, CS ;
CORBETT, PJ .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1992, 84 (09) :683-689
[9]   Lung and heart dose volume analyses with CT simulator in radiation treatment of breast cancer [J].
Das, IJ ;
Cheng, EC ;
Freedman, G ;
Fowble, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (01) :11-19
[10]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122