Gradient correction and classification of CT lung images for the automated quantification of mosaic attenuation pattern

被引:14
作者
Chabat, F [1 ]
Desai, SR [1 ]
Hansell, DM [1 ]
Yang, GZ [1 ]
机构
[1] Royal Brompton Hosp, Imperial Coll Sci Technol & Med, London SW3 6NP, England
关键词
lungs; diseases; anatomy; computed tomography; techniques; attenuation values; physics and instrumentation;
D O I
10.1097/00004728-200005000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The detection of density differences, or "mosaic attenuation pattern," on CT images may be difficult when the regional inhomogeneity of the density of the lung parenchyma is subtle. The purpose of this work was to develop a fully automated method for the reproducible quantification of the underattenuated areas of the lung parenchyma. This technique may be useful in increasing the precision of investigation of structure/function relationships. Method: Anatomical segmentation was achieved by a structure-filtering operator based on mathematical morphology. To compensate for the density gradient visible on lung CT scans, a model-based iterative deconvolution filter and an adaptive clustering algorithm were developed. Validation was performed with CT images from a lung phantom, 15 patients with constrictive obliterative bronchiolitis, and 8 normal subjects. Results: The accuracy of the estimate of the density gradient on phantom studies was 93.3%. The automated quantification of the areas of decreased attenuation on scans of constrictive obliterative bronchiolitis was within 8.2% from the average scoring of two experienced observers. Conclusion: The proposed technique is fully automated and can accurately correct for density gradient and classify areas of decreased attenuation on lung CT images.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 16 条
[1]   Density gradient of the lung parenchyma at computed tomographic scanning in patients with pulmonary hypertension and systemic sclerosis [J].
Cailes, JB ;
duBois, RM ;
Hansell, DM .
ACADEMIC RADIOLOGY, 1996, 3 (09) :724-730
[2]   EFFICIENT IMPLEMENTATION OF THE FUZZY C-MEANS CLUSTERING ALGORITHMS [J].
CANNON, RL ;
DAVE, JV ;
BEZDEK, JC .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1986, 8 (02) :248-255
[3]  
DeGroot M. H., 1989, PROBABILITY STAT
[4]  
Devroye L., 1986, NONUNIFORM RANDOM VA
[5]   A comparison of methods for enhancing the detection of areas of decreased attenuation on CT caused by airways disease [J].
Fotheringham, T ;
Chabat, F ;
Hansell, DM ;
Wells, AU ;
Desai, SR ;
Gückel, C ;
Padley, SPG ;
Gibson, M ;
Yang, GZ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) :385-389
[6]   Obliterative bronchiolitis: Individual CT signs of small airways disease and functional correlation [J].
Hansell, DM ;
Rubens, MB ;
Padley, SPG ;
Wells, AU .
RADIOLOGY, 1997, 203 (03) :721-726
[7]   CT densitometry of the lungs: Scanner performance [J].
Kemerink, GJ ;
Lamers, RJS ;
Thelissen, GRP ;
vanEngelshoven, JMA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) :24-33
[8]   THE UNRELIABILITY OF CT-NUMBERS AS ABSOLUTE VALUES [J].
LEVI, C ;
GRAY, JE ;
MCCULLOUGH, EC ;
HATTERY, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (03) :443-447
[9]   GRAVITY-DEPENDENT ATELECTASIS - RADIOLOGIC, PHYSIOLOGIC AND PATHOLOGIC CORRELATION IN RABBITS ON HIGH-FREQUENCY OSCILLATION VENTILATION [J].
MORIMOTO, S ;
TAKEUCHI, N ;
IMANAKA, H ;
NISHIMURA, M ;
TAKEZAWA, J ;
TAENAKA, N ;
MATSUURA, N ;
TOMODA, K ;
IKEZOE, J ;
ARISAWA, J ;
HAMADA, S ;
TAKASHIMA, S ;
KOZUKA, T .
INVESTIGATIVE RADIOLOGY, 1989, 24 (07) :522-530
[10]  
Naidich DP, 1999, COMPUTED TOMOGRAPHY