Thermal performance criteria of elliptic tube bundle in crossflow

被引:149
作者
Ibrahim, Talaat A. [2 ]
Gomaa, Abdalla [1 ]
机构
[1] Helwan Univ, Fac Ind Educ, Abdalla Gomaa Refrigerat & Air Conditioning Dept, Cairo 11887, Egypt
[2] King Saud Univ, Riyadh 11577, Saudi Arabia
关键词
Thermal performance criteria; Turbulent flow; Elliptic tube bundle; FIN HEAT-EXCHANGERS; FORCED-CONVECTION; NUMERICAL-SIMULATION; OPTIMIZATION; FIELD;
D O I
10.1016/j.ijthermalsci.2009.03.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the thermofluid characteristics of the elliptic tube bundle in crossflow have been investigated. Experimental and numerical investigations of the turbulent flow through bundle of elliptic tubes heat exchanger are carried out with a particular reference to the circular tube bundle. The investigation covers the effects of key design parameters of Reynolds numbers (5600-40,000), minor-to-major axis ratios (0.25, 0.33. 0.5 and 1) and flow angles of attack (0-150 degrees). Five bundles of elliptic tube heat exchangers with different axis ratios were designed and manufactured in staggered manner. Numerical CFD modeling using finite volume discretization method was conducted to predict the system performance extensively. Four methods were presented to resort a metric that expresses the thermal performance criteria of the elliptic tube bundle. The results indicated that, increasing the angle of attack clockwise until 90 degrees enhances the convective heat transfer coefficient considerably. The maximum thermal performance under constraint of a fixed pumping power or a mass flow rate was obtained at a zero angle of attack and the minimum thermal performance occurred at an angle of attack equals 90 degrees. The best thermal performance of the elliptic tube heat exchanger was qualified with the lower values of Reynolds number, axis ratio and angle of attack. (c) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:2148 / 2158
页数:11
相关论文
共 21 条
[1]  
Afify R., 2004, ENG RES J, V96, pM37
[2]   Forced convection from a straight elliptical tube [J].
Badr, HM .
HEAT AND MASS TRANSFER, 1998, 34 (2-3) :229-236
[3]  
Bergles A., 1974, 4 INT HEAT TRANSF C, V2, P239
[4]   Numerical evaluation of alternate tube configurations for particle deposition rate reduction in heat exchanger tube bundles [J].
Bouris, D ;
Papadakis, G ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2001, 22 (05) :525-536
[5]  
*FLUENT INC, 2005, FLUENT US MAN
[6]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[7]  
Gomaa A., 1999, IMECHE 6 UK NAT C HE, P205
[8]   Measurements of the overall heat transfer from combustion gases confined within elliptical tube heat exchangers [J].
Harris, DK ;
Goldschmidt, VW .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (01) :33-37
[9]  
Holman J.P., 1978, Experimental Methods for Engineers
[10]  
JANG J, 1996, 4 INT S HEAT TRANSF, P547