Simultaneous comparison of thoracic bioimpedance and arterial pulse waveform-derived cardiac output with thermodilution measurement

被引:29
作者
Hirschl, MM
Kittler, H
Woisetschläger, C
Siostrzonek, P
Staudinger, T
Kofler, J
Oschatz, E
Bur, A
Gwechenberger, M
Laggner, AN
机构
[1] Univ Vienna, Dept Emergency Med, Vienna, Austria
[2] Univ Vienna, Dermatol Clin, Vienna, Austria
[3] Univ Vienna, Clin Internal Med 2, Dept Cardiol, Vienna, Austria
[4] Univ Vienna, Clin Internal Med 1, Crit Care Unit, Vienna, Austria
关键词
thermodilution method; thoracic electrical bioimpedance; cardiac output; noninvasive; critically ill patients; emergency medicine; intensive care medicine; pulmonary artery catheter; stroke volume;
D O I
10.1097/00003246-200006000-00017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the accuracy and reliability of thoracic electrical bioimpedance (TEB) and the arterial pulse waveform analysis with simultaneous measurement of thermodilution cardiac output (TD-CO) in critically ill patients. Design: Prospective data collection. Setting: Emergency department and critical care unit in a 2,000-bed inner-city hospital. Patients: A total of 29 critically ill patients requiring invasive hemodynamic monitoring for clinical management were prospectively studied. Interventions: Noninvasive cardiac output was simultaneously measured by a TEE device and by analysis of the arterial pulse waveform derived from the finger artery. Invasive cardiac output was determined by the thermodilution technique. Measurements and Main Results: A total of 175 corresponding TD-CO and noninvasive hemodynamic measurements were collected in 30-min intervals. They revealed an overall bias of 0.34 L/min/m(2) (95% confidence interval, 0.24-0.44 L/min/m(2); p < .001) for the arterial pulse waveform analysis and of 0.61 L/min/m(2) (95% confidence interval, 0.50-0.72 L/min/m(2); p < .001) for the TEE. In 39.4% (n = 69) of all measurements, the discrepancy between arterial pulse waveform analysis and To-so was >0.50 L/min/m(2). The discrepancies of the arterial pulse waveform analysis correlated positively with the magnitude of the cardiac index (r(2) = 0.29; p < .001). In 56.6% (n = 99) of ail measurements, the discrepancy between TEE and To-Go was >0.50 L/min/m(2). The magnitude of the discrepancies of the TEE was significantly correlated with age (r(2) = 0.17; p = .02). Measurements were in phase in 93.2% of all arterial pulse waveform analysis and in 84.9% of all TEE readings (p < .001). Conclusions: The arterial pulse waveform analysis exhibits a greater accuracy and reliability as compared with the TEE with regard to overall bias, number of inaccurate readings, and phase lags. The arterial pulse waveform analysis may be useful for the monitoring of hemodynamic changes. However, both methods fail to be a substitute for the TD-GO because of a substantial percentage of inaccurate readings.
引用
收藏
页码:1798 / 1802
页数:5
相关论文
共 36 条
  • [1] Becker K, 1998, J CARDIOTHOR VASC AN, V12, P13
  • [2] CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE
    BERNSTEIN, DP
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (10) : 898 - 901
  • [3] A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE
    BERNSTEIN, DP
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (10) : 904 - 909
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] BOLDT J, 1994, CRIT CARE MED, V22, P1913
  • [6] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [7] DOES PULMONARY-ARTERY CATHETERIZATION BENEFIT PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION
    DALEN, JE
    [J]. CHEST, 1990, 98 (06) : 1313 - 1314
  • [8] DOBB GJ, 1987, INTENS CARE MED, V13, P304
  • [9] PREDICTORS OF BETWEEN-METHOD DIFFERENCES IN CARDIAC-OUTPUT MEASUREMENT USING THORACIC ELECTRICAL BIOIMPEDANCE AND THERMODILUTION
    DOERING, L
    LUM, E
    DRACUP, K
    FRIEDMAN, A
    [J]. CRITICAL CARE MEDICINE, 1995, 23 (10) : 1667 - 1673
  • [10] Non-invasive estimations of ventricular ejection time and stroke volume: Comparison of impedance cardiography and the Portapres 2
    Fahrenberg, J
    Foerster, F
    Muller, W
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1997, 21 (01) : 15 - 22